A fix is available
APAR status
Closed as program error.
Error description
KO2O1916E IFI COLLECTOR FAILED . abends0c1 in ko2ccaf2, csect fpeufi24. trying to invoke FUDA services after CCAF task was already detached.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - OMEGAMON Server * * - PE Server * * - Common Collector * * - Classic Interface * **************************************************************** * PROBLEM DESCRIPTION: When the OMEGAMON Server is started * * and the start up of the server * * subtask PESERVER is disabled in the * * start up configuration member, the * * first user logon to the Classic * * interface opens the VTAM session which * * then owns the server log (SYSPRINT) * * instead of the server subtask PESERVER. * * When the first VTAM session terminates * * during logoff, the server log is * * closed. Consecutive messages which * * shall be written to the server log will * * cause an Abend 0C1. * * * * for V310 * * The service level of the * * OMEGAMON Server subtask PESERVER * * FPEV0000I DATA SERVER INITIALIZATION * * FPEV0114I PTF BUILD IS 07.143 * * * * for V410 * * The service level of the * * OMEGAMON Server subtask PESERVER * * FPEV0000I DATA SERVER INITIALIZATION * * FPEV0114I PTF BUILD IS 07.143 * * * * * * * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** Abend 0C1 when a message is issued to the closed server log (SYSPRINT).
Problem conclusion
The code has been corrected. KEYWORDS : ABEND 0C1 VTAM CLASSIC INTERFACE KO2O1916E IFI COLLECTOR FAILED PESERVER
Temporary fix
Comments
APAR Information
APAR number
PK24321
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-05-02
Closed date
2007-05-24
Last modified date
2007-06-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK25439 UK25440
Modules/Macros
DGOVMSTR FPEUFWMX KD260SO1 KD261SO1 KO2OMSGB
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]