IBM Support

PK21939: ENHANCE THE HANDLING OF MODIFIABLE PCBS VIA CHNG AND INQY CALLS TO ELIMINATE THE NECESSITY OF BACKING OUT THE MESSAGE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • Application issues a CHNG to a modifiable PCB followed by an
    INQY call to determine if the path is active.   If the path is
    active the application issues an ISRT call.  With Apar PK11802,
    WLR moved its logic from the CHNG call to the ISRT call to
    support both modifiable and non-modifiable PCBs.   However, the
    INQY call is based upon the destination.   If the application
    moves the INQY call after the ISRT, the INQY will check the
    correct destination; however, the application must also be
    updated to back out the message. WLR is being updated to
    move its logic for handling modifiable PCBs back to the CHNG
    exit. The ISRT exit will still be used to handle
    non-modifiable PCBs.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of WLR who are on IMS V8.1         *
    *                 or IMS V9.1.                                 *
    ****************************************************************
    * PROBLEM DESCRIPTION: Enhance the handling of modifiable PCBS *
    *                      via CHNG and INQY calls to eliminate    *
    *                      the necessity of backing out the        *
    *                      message.                                *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Application issues a CHNG to a modifiable PCB followed by an
    INQY call to determine if the path is active. If the path is
    active the application issues an ISRT call. With Apar PK11802,
    WLR moved its logic from the CHNG call to the ISRT call to
    support both modifiable and non-modifiable PCBs. However, the
    INQY call is based upon the destination. If the application
    moves the INQY call after the ISRT, the INQY will check the
    correct destination; however, the application must also be
    updated to back out the message.
    

Problem conclusion

Temporary fix

Comments

  • WLR is being updated to move its logic for handling modifiable
    PCBs back to the CHNG exit. The ISRT exit will still be used to
    handle non-modifiable PCBs.
    

APAR Information

  • APAR number

    PK21939

  • Reported component name

    IMS WLR

  • Reported component ID

    5697B8700

  • Reported release

    240

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2006-03-21

  • Closed date

    2006-03-27

  • Last modified date

    2006-04-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK13050 UK13051

Modules/Macros

  •    IWXCTRX0 IWXGEN   IWXMSCE1 IWXMSCPR
    

Fix information

  • Fixed component name

    IMS WLR

  • Fixed component ID

    5697B8700

Applicable component levels

  • R240 PSY UK13050

       UP06/03/29 P F603

  • R243 PSY UK13051

       UP06/03/29 P F603

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.