Error description
While testing DRF Beta and Incremental Image Copy batch function - stop a database and take a batch image copy. - start the database, and enter online transactions which will update the database - /DBR the database without NOFEOV, which produces a SLDS containing the database updates. - start the database. - submit the batch DRF IIC job. - ** batch DRF job goes into a wait state and displays the following message - FRD6003I SYTUND SYTUND AUTHORIZED BY PROD LOCAL FIX: If a /DBR is done to the database, then the DRF batch job completes. This is not how it is expected to work. This DRF resolution is in support of IMS APAR and HPIC APAR.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users with IMS Database Recovery * * Facility Version 3 Release 1 installed. * **************************************************************** * PROBLEM DESCRIPTION: Databases and Areas must be stopped in * * order to take a DRF incremental image * * copy (OUTPUT(ICR)). * **************************************************************** * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** DRF has been changed to take both batch and concurrent ICRs (incremental image copies). If all the required logs are available, the image copy is registered to DBRC as batch and the RUNTIME is the current time. If only a subset of the required logs are available, the image copy is registered as concurrent and the RUNTIME is the latest stoptime of all the log data sets used. The STOPTIME of this image copy is the current time.
Problem conclusion
DRF has been changed to take both batch and concurrent ICRs (incremental image copies). If all the required logs are available image copy is registered to DBRC as batch and the RUNTIME is the current time. If only a subset of the required logs are available image copy is registered concurrent and the RUNTIME is the latest stoptime of all the log data sets used. The STOPTIME of this image copy is the current time. If there have been no changes since the last image copy, meaning that an image copy record with the same RUNTIME exists, DRF issues message FRD6022A with the reason IMAGE COPY ALREADY TAKEN Message 'FRD6003I dbname AUTHORIZED BY ssid' is issued when an ADD control statement is processed if any of the databases are authorized. This is partly for information only. This message is no longer issued when OUTPUT(ICR) is specified. Incremental image copies to a specified time (or what would be called timestamp incremental image copy) are not allowed. The RCVTIME parameter on the START control statement is not allowed when OUTPUT(ICR) is specified. Error message FRD6124A INVALID DATA ENCOUNTERED. KEYWORD: RCVTIME RSN=SPECIFIC VALUE OF RCVTIME IS NOT ALLOWED FOR AN INCREMENTAL IMAGE COPY is issued and the job fails. An image copy can be created as part of the normal recovery process, but an incremental image copy is not designed for timestamp image copies. DRF has also been changed to call auxilliary utilities with the correct list of DBDSs and areas to be processed. Only those that can be recovered are passed. ---- The following changes are made to the IMS Database Recovery Facility for z/OS User's Guide and Reference Version 3 Release 1 manual number SC18-9407-00. Message FRD6022A adds a new reason: IMAGE COPY ALREADY TAKEN OUTPUT(ICR) option was specified, however there have been no changes since the last incremental image copy was taken. The System action for this reason is: This is not an error situation but an informational message. No action is required. Message FRD6124A adds a new reason: SPECIFIC VALUE OF RCVTIME IS NOT ALLOWED FOR AN INCREMENTAL IMAGE COPY The OUTPUT(ICR) option was specified and RCVTIME was specified on the RECOVER START input control statement. This combination is not allowed, an incremental image copy cannot be taken to a specified time. If a timestamp recovery is desired along with an image copy, remove the OUTPUT(ICR) option. On page 72 under the IC option of the ADD control statement, there is a paragraph beginning with 'Only the batch image copy feature of HPIC is available ...' After this paragrpafh, add the following: When the OUTPUT(ICR) option is specified, the incremental image copy created may be batch or concurrent. A concurrent image copy is created when only a subset of the required logs are available. The RUNTIME used to register the image copy to DBRC is the latest stoptime of all the log data sets used as input. It is not necessary to stop the database for an incremental image copy.
Temporary fix
Comments
APAR Information
APAR number
PK21934
Reported component name
IMS DB RECOVERY
Reported component ID
5655I4400
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2006-03-21
Closed date
2006-06-28
Last modified date
2006-07-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK15870
Modules/Macros
FRXADF00 FRXADM10 FRXADM20 FRXBDMG0 FRXEDRF0 FRXEPSS0 FRXIAUX FRXICTL0 FRXIDYN0 FRXIOCN0 FRXIOSM0 FRXIVCN0 FRXIVSM0 FRXMTC FRXRVIC FRXRWCE FRXTAS00 FRXUAPI0 FRXVADD0 FRXVRCV0 FRXVSTA0 FRXVSTA1
| SC18940700 |
Fix information
Fixed component name
IMS DB RECOVERY
Fixed component ID
5655I4400
Applicable component levels
R310 PSY UK15870
UP06/06/30 P F606
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88Z","label":"IMS Database Recovery Facility"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: