PK19395: IPR DRIVER SHOULD TURN OFF PARTITION INIT NEEDED FLAG

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible in next release.

Error description

  • After reorganizing a HALDB, the Partition Init Needed flag is
    not turned off for each partition in DBRC.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IPR Driver of IMS Parallel      *
    *                 Reorganization for z/OS Version 3 Release 1  *
    *                 (FMID=H25N310)                               *
    ****************************************************************
    * PROBLEM DESCRIPTION: After reorganizing HALDB, the Partition *
    *                      Init Needed flag is not turned off for  *
    *                      each partition in RECON.                *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    IPR Driver does not turn off the PARTITION INIT NEEDED flag for
    HALDB partitions on RECON.
    

Problem conclusion

Temporary fix

Comments

  • IPR Driver has been modified so that IPR Driver turn off the
    Partition Init Needed flag for each partition in RECON.
    ========================
    = DOCUMENTATION CHANGE =
    ========================
    IMS Parallel Reorganization for z/OS Version 3 Release 1
    User's Guide (SC18922801) should be changed as follows:
    ================================================================
     Chapter 2. IMS Parallel Reorganization Driver
     2.7   Control statements
     2.7.8 Description of control statements for Reorganization
           Manager
     2.7.8.17 NAMESWAP control statement
    
     :
     If you specify NAMESWAP=YES and the data set name swapping
     succeeds, Reorganization Manager issues DBRC NOTIFY.REORG
     commands for the reorganized database and the primary index.
    |For each HALDB partition, if the PARTITION INIT NEEDED flag
    |in RECON is on, the DBRC command CHANGE.DB NOPINIT is issued
    |before NOTIFY.REORG commands.
    |If the active DBDS is the M-through-V and Y side, the DBRC
     command CHANGE.DB OLRDBDS(A) is issued. If you specify
     INDEXBLD=YES, the NOTIFY.REORG command is also issued for each
     secondary index.
     :
    ================================================================
     2.9 Post-reorganization processing
     2.9.3 Manual DBRC notification processing
    
     The DBRC notification processing must be done after the data
     set name swapping. If you specified ILDSBLD=NO in the preceding
     IPR Driver job for a HALDB and it should have non-empty ILDSs,
     you must rebuild ILDS for each partition that has been
     reorganized by the IPR Driver job before doing the DBRC
     notification processing explained below. You can use IMS HALDB
     Index/ILDS Rebuild Utility (DFSPREC0) to rebuild ILDSs.
     The way the DBRC notification processing is done varies at
     installations, but a typical sequence of steps is:
    
    | 1. For a HALDB, you need to issue the command to turn off
    |    the PARTITION INIT NEEDED flag for each partition,
    |    because all the specified partitions have been
    |    initialized before reloading segments.
    |       CHANGE.DB DBD(part_name) NOPINIT
    |
    | 2 Notify DBRC that the reorganization has taken place.
        For a non-HALDB, issue the following commands for all DD
        names of the reorganized database and primary index.
        For a HALDB, issue the command for each partition
        and each DD name of the partition except the DD name
        for ILDS and the primary index of PHIDAM.
            NOTIFY.REORG DBD(dbd_or_part_name) DDN(ddname)
    
     :
    ================================================================
     Chapter 10. Messages and Codes
     10.3 Messages
     10.3.2 HPSG Messages
    ----------------------------------------------------------------
    HPSG0316I CHANGE.DB DBD(dbdname) parameter
     Explanation: The CHANGE.DB command has been successfully
     completed for the database or HALDB partition dbdname.
     parameter is one of the following:
     -OLRDBDS(A)
     -READON
     -NOAUTH
     -AUTH READOFF
     -NOAUTH READOFF
     -AUTH READON
     -NOAUTH READON
    |-NOPINIT
    System Action: The IPR Driver continues processing.
    Programmer Response: None.
    ----------------------------------------------------------------
     HPSG0316E CHANGE.DB DBD(dbdname) parameter --- ERROR (CC=xx)
     Explanation: An error occurred when the IPR Driver issued the
     CHANGE.DB command for the database or a HALDB partition
     dbdname. The condition code returned from DSPURX00 is xx.
     parameter Report of Reference
     -OLRDBDS(A)
       DBRC AUTHORIZATION PROCESSING FOR NAME SWAPPING
     -READON
       DBRC AUTHORIZATION PROCESSING FOR REORGANIZATION
     -NOAUTH
       DBRC AUTHORIZATION PROCESSING FOR REORGANIZATION
       or
       DBRC AUTHORIZATION PROCESSING FOR NAME SWAPPING
     -AUTH READOFF
       DBRC NOTIFICATION PROCESSING
    |-NOPINIT
    |  DBRC NOTIFICATION PROCESSING
     If the preceding HPSG0410I message was issued, see the report
     titled "DBRC PROCESSING FOR RESTORING AUTHORIZATION FLAGS."
     System Action: The IPR Driver ends with a return code of 8.
     Programmer Response: Refer to the messages issued from the DBRC
     utility, and identify the cause of the error. The messages are
     printed in the HPSOUT2 data set.
    ======================= End of Doc-Change ======================
    

APAR Information

  • APAR number

    PK19395

  • Reported component name

    IMS PARALLEL RE

  • Reported component ID

    5655F7400

  • Reported release

    310

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2006-02-08

  • Closed date

    2006-03-02

  • Last modified date

    2006-04-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK12234

Modules/Macros

  •    HPSGGRMB HPSGRS00 HPSGRS30
    

Publications Referenced
SC18922801    

Fix information

  • Fixed component name

    IMS PARALLEL RE

  • Fixed component ID

    5655F7400

Applicable component levels

  • R310 PSY UK12234

       UP06/03/03 P F603

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.