A fix is available
APAR status
Closed as unreproducible in next release.
Error description
After reorganizing a HALDB, the Partition Init Needed flag is not turned off for each partition in DBRC.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IPR Driver of IMS Parallel * * Reorganization for z/OS Version 3 Release 1 * * (FMID=H25N310) * **************************************************************** * PROBLEM DESCRIPTION: After reorganizing HALDB, the Partition * * Init Needed flag is not turned off for * * each partition in RECON. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** IPR Driver does not turn off the PARTITION INIT NEEDED flag for HALDB partitions on RECON.
Problem conclusion
Temporary fix
Comments
IPR Driver has been modified so that IPR Driver turn off the Partition Init Needed flag for each partition in RECON. ======================== = DOCUMENTATION CHANGE = ======================== IMS Parallel Reorganization for z/OS Version 3 Release 1 User's Guide (SC18922801) should be changed as follows: ================================================================ Chapter 2. IMS Parallel Reorganization Driver 2.7 Control statements 2.7.8 Description of control statements for Reorganization Manager 2.7.8.17 NAMESWAP control statement : If you specify NAMESWAP=YES and the data set name swapping succeeds, Reorganization Manager issues DBRC NOTIFY.REORG commands for the reorganized database and the primary index. |For each HALDB partition, if the PARTITION INIT NEEDED flag |in RECON is on, the DBRC command CHANGE.DB NOPINIT is issued |before NOTIFY.REORG commands. |If the active DBDS is the M-through-V and Y side, the DBRC command CHANGE.DB OLRDBDS(A) is issued. If you specify INDEXBLD=YES, the NOTIFY.REORG command is also issued for each secondary index. : ================================================================ 2.9 Post-reorganization processing 2.9.3 Manual DBRC notification processing The DBRC notification processing must be done after the data set name swapping. If you specified ILDSBLD=NO in the preceding IPR Driver job for a HALDB and it should have non-empty ILDSs, you must rebuild ILDS for each partition that has been reorganized by the IPR Driver job before doing the DBRC notification processing explained below. You can use IMS HALDB Index/ILDS Rebuild Utility (DFSPREC0) to rebuild ILDSs. The way the DBRC notification processing is done varies at installations, but a typical sequence of steps is: | 1. For a HALDB, you need to issue the command to turn off | the PARTITION INIT NEEDED flag for each partition, | because all the specified partitions have been | initialized before reloading segments. | CHANGE.DB DBD(part_name) NOPINIT | | 2 Notify DBRC that the reorganization has taken place. For a non-HALDB, issue the following commands for all DD names of the reorganized database and primary index. For a HALDB, issue the command for each partition and each DD name of the partition except the DD name for ILDS and the primary index of PHIDAM. NOTIFY.REORG DBD(dbd_or_part_name) DDN(ddname) : ================================================================ Chapter 10. Messages and Codes 10.3 Messages 10.3.2 HPSG Messages ---------------------------------------------------------------- HPSG0316I CHANGE.DB DBD(dbdname) parameter Explanation: The CHANGE.DB command has been successfully completed for the database or HALDB partition dbdname. parameter is one of the following: -OLRDBDS(A) -READON -NOAUTH -AUTH READOFF -NOAUTH READOFF -AUTH READON -NOAUTH READON |-NOPINIT System Action: The IPR Driver continues processing. Programmer Response: None. ---------------------------------------------------------------- HPSG0316E CHANGE.DB DBD(dbdname) parameter --- ERROR (CC=xx) Explanation: An error occurred when the IPR Driver issued the CHANGE.DB command for the database or a HALDB partition dbdname. The condition code returned from DSPURX00 is xx. parameter Report of Reference -OLRDBDS(A) DBRC AUTHORIZATION PROCESSING FOR NAME SWAPPING -READON DBRC AUTHORIZATION PROCESSING FOR REORGANIZATION -NOAUTH DBRC AUTHORIZATION PROCESSING FOR REORGANIZATION or DBRC AUTHORIZATION PROCESSING FOR NAME SWAPPING -AUTH READOFF DBRC NOTIFICATION PROCESSING |-NOPINIT | DBRC NOTIFICATION PROCESSING If the preceding HPSG0410I message was issued, see the report titled "DBRC PROCESSING FOR RESTORING AUTHORIZATION FLAGS." System Action: The IPR Driver ends with a return code of 8. Programmer Response: Refer to the messages issued from the DBRC utility, and identify the cause of the error. The messages are printed in the HPSOUT2 data set. ======================= End of Doc-Change ======================
APAR Information
APAR number
PK19395
Reported component name
IMS PARALLEL RE
Reported component ID
5655F7400
Reported release
310
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2006-02-08
Closed date
2006-03-02
Last modified date
2006-04-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK12234
Modules/Macros
HPSGGRMB HPSGRS00 HPSGRS30
| SC18922801 |
Fix information
Fixed component name
IMS PARALLEL RE
Fixed component ID
5655F7400
Applicable component levels
R310 PSY UK12234
UP06/03/03 P F603
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSVL5Q","label":"IMS Database Reorganization Expert for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310"}]
Document Information
Modified date:
06 January 2023