IBM Support

PK16728: HPIC VIC PROCESS ABEND S0CB BECAUSE OF INSUFFICIENT WORK AREA.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • HPIC issues a DBRC command for VIC proceesing but it does not
    GETMAIN enough work area.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Image Copy for z/OS *
    *                 Version 3 Release 2 users ( FMID=H1J0320 )   *
    ****************************************************************
    * PROBLEM DESCRIPTION: HPIC terminated with ABEND S0CB         *
    *                      ( ABEND0CB ) as GETMAIN fail            *
    *                      for work area of NOTIFY.UIC command     *
    *                      when VIC=Y is specified and processed   *
    *                      DBs are more than 900 DBs.              *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    HPIC terminated with ABEND S0CB ( ABEND0CB ) as GETMAIN fail
    of storage shortage for work area of NOTIFY.UIC command when
    VIC=Y is specified and processed DBs are more than 900 DBs.
    Because HPIC uses the total size of all of ICDS included other
    than VIC for getmain of work are for NOTIFY.UIC command.
    

Problem conclusion

  • The module FABJUIC1 has been modified following things:
    -to getmain for NOTIFY.UIC work area as 256 DBDS.
    -to build command for a maximum of 256 VIC at one NOTIFY.UIC
     command and repeat for all index dbds.
    
    The module FABJCMDB has been modified to build a maximum of 256
    NOTIFY.UIC COMMAND at one time.
    
    The module FABJMAIN has been modified to call FABJIDX7, FABJIDX8
    and FABJIDX9 with FUNC=free is specified.
    
    The macro FABJIDXN has been modified to freemain internal work
    area of HPIC.
    
    The module FABJIDX7, FABJIDX8, AND FABJIDX9 have been
    re-assembled.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK16728

  • Reported component name

    IMS HP IMAGE CO

  • Reported component ID

    5655K9600

  • Reported release

    320

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2005-12-14

  • Closed date

    2005-12-16

  • Last modified date

    2006-01-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK10157

Modules/Macros

  • FABJCMDB FABJIDXN FABJIDX7 FABJIDX8 FABJIDX9
    FABJMAIN FABJUIC1
    

Fix information

  • Fixed component name

    IMS HP IMAGE CO

  • Fixed component ID

    5655K9600

Applicable component levels

  • R320 PSY UK10157

       UP05/12/17 P F512

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"320","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
14 December 2020