A fix is available
APAR status
Closed as program error.
Error description
HPIC job with HPIO=Y, for OSAM data base, causes PPRC to be suspended and with HPIO=N causes abend U0097.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IMS High Performance Image Copy for z/OS * * Version 4 Release 1 users ( FMID=H1J0410 ) * **************************************************************** * PROBLEM DESCRIPTION: This APAR includes fixes for following * * problems: * * - HPIC Recovery function causes the * * PPRC to be suspended, when HPIC * * processes the OSAM database and * * HPIO=Y is specified. * * - HPIC Recovery function terminates * * with U0097 ( ABENDU0097 ), when HPIC * * processes the OSAM database and * * HPIO=N is specified. * * - HPIC Image Copy function sets the * * incorrect value to the header record * * of the image copy data set for the * * secondary index DB, when type-A image * * copy process under IMS Parallel * * Reorganization for z/OS Version 3 * * Release 1 with INDEXBLD=YES is * * requested. * **************************************************************** * RECOMMENDATION: * **************************************************************** This APAR includes fixes for following problems: - HPIC Recovery function causes the PPRC to be suspended, when HPIC processes the OSAM database and HPIO=Y is specified. Because the PPRC suspends are caused by HPIC with HPIO=Y option that is building CCW chains with "short domains". - HPIC Recovery function terminates with U0097 ( ABENDU0097 ), when HPIC processes the OSAM database and HPIO=N is specified. Because HPIC mishandles the return code from FABJOINT. - HPIC Image Copy function sets the incorrect value to the header record of the image copy data set for the secondary index DB, when type-A image copy process under IMS Parallel Reorganization for z/OS Version 3 Release 1 with INDEXBLD=YES is requested.
Problem conclusion
FABJOINT has been modified to put a correct count of write CCWs into each LR. FABJRDB7, FABJRDB8, and FABJRDB9 have been modified to bypass OPEN macro with TYPE=J option for OSAM database, when HPIO=N is specified. FABJRDB7, and FABJRDB8 have been modified to check correctly the return code from FABJOINT called by the OPEN request. FABJDRQS has been reassembled.
Temporary fix
Comments
APAR Information
APAR number
PK16726
Reported component name
IMS HP IMAGE CO
Reported component ID
5655K9600
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2005-12-14
Closed date
2006-01-10
Last modified date
2006-02-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK10644
Modules/Macros
FABJDRQS FABJOINT FABJRDB7 FABJRDB8 FABJRDB9
Fix information
Fixed component name
IMS HP IMAGE CO
Fixed component ID
5655K9600
Applicable component levels
R410 PSY UK10644
UP06/01/11 P F601
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"4.1.0","Line of Business":{"code":"","label":""}}]