IBM Support

PK15598: HPIC RESTART CANNOT WORK IF THE OUTPUT IC DATA SET IS A GDG.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • HPIC RESTART checks output data set name in previous execution.
    However, if the dataset is a GDG, the data set name should
    be different from the previous execution.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Image Copy for z/OS *
    *                 Version 4 Release 1 users ( FMID=H1J0410 )   *
    ****************************************************************
    * PROBLEM DESCRIPTION: HPIC RESTART process can not work when  *
    *                      the output IC data set is a GDG.        *
    *                      Because HPIC checks the output IC data  *
    *                      set name in previous run.               *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    HPIC RESTART process can not work if the output IC data set is
    a GDG.
    HPIC compares previous IC data set name and current one. But
    the data set name might be different, when you uses GDG, or
    time stamp in the data set name.
    

Problem conclusion

  • The module FABJXCR has been modified not to check previous
    output dataset name of image copy.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK15598

  • Reported component name

    IMS HP IMAGE CO

  • Reported component ID

    5655K9600

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2005-11-21

  • Closed date

    2005-11-28

  • Last modified date

    2005-12-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK09509

Modules/Macros

  • FABJXCR
    

Fix information

  • Fixed component name

    IMS HP IMAGE CO

  • Fixed component ID

    5655K9600

Applicable component levels

  • R410 PSY UK09509

       UP05/11/30 P F511

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"4.1.0","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
14 December 2020