IBM Support

PK14099: HPIC ABENDS WITH S0C4 (ABEND0C4) BECAUSE HPIC USES INCORRECT REGISTER FOR IMS INTERFACE.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • HPIC abends with an S0C4 because HPIC uses an incorrect register
    for the IMS interface macro and forgot to reset the following
    step. At that point, HPIC could not map internal control block
    correctly.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Image Copy for z/OS *
    *                 Version 3 Release 2 users ( FMID=H1J0320 )   *
    ****************************************************************
    * PROBLEM DESCRIPTION: HPIC V3R2 CIC function terminates with  *
    *                      ABEND S0C4 ( ABEND0C4 ) in the module   *
    *                      FABJDMP8.                               *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    HPIC V3R2 CIC function runs by the incorrect processing type,
    and terminates with ABEND S0C4 ( ABEND0C4 ) in the module
    FABJDMP8.
    Because HPIC CIC uses incorrect register for mapping internal
    control block.
    

Problem conclusion

  • FABJDMPN has been modified to set correct address of HPIC
    control block into register.
    
    FABJDMP7, FABJDMP8 and FABJDMP9 have been reassembled.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK14099

  • Reported component name

    IMS HP IMAGE CO

  • Reported component ID

    5655K9600

  • Reported release

    320

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2005-10-26

  • Closed date

    2005-11-01

  • Last modified date

    2005-12-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK08642

Modules/Macros

  • FABJDMPN FABJDMP7 FABJDMP8 FABJDMP9
    

Fix information

  • Fixed component name

    IMS HP IMAGE CO

  • Fixed component ID

    5655K9600

Applicable component levels

  • R320 PSY UK08642

       UP05/11/02 P F511

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"320","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
14 December 2020