Error description
When VIC=Y,HDPC=Y or HDPC=O is specified, HPIC regards null key of the first reecord in HIDAM Index as an error record and issues message DFS330A.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IMS High Performance Image Copy for z/OS * * Version 3 Release 2 users ( FMID=H1J0320 ) * **************************************************************** * PROBLEM DESCRIPTION: HPIC V3R2 Image Copy function * * terminates with RC=16 and the message * * DFS330A ( MSGDFS330A ) for key sequence * * error of a primary index DB or * * a secondary index DB, when HDPC=O or * * both of HDPC=Y and VIC=Y keywords are * * specified in the ICEIN control * * statement and the first index key is * * null. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** HPIC V3R2 Image Copy function terminates with RC=16 and the message DFS330A ( MSGDFS330A ) for key sequence error of a primary index DB or a secondary index DB, when HDPC=O or both of HDPC=Y and VIC=Y keywords are specified in the ICEIN control statement and the first index key is null. When the first index key is null, HPIC mishandles regarding the null key as an error key.
Problem conclusion
FABJDPSN has been modified to bypass the key sequence check of the first record in the index DB, when the virtual image copy process with pointer checking is applied for the index DB. FABJDPS7, FABJDPS8, and FABJDPS9 have been reassembled.
Temporary fix
Comments
APAR Information
APAR number
PK13486
Reported component name
IMS HP IMAGE CO
Reported component ID
5655K9600
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2005-10-14
Closed date
2005-10-26
Last modified date
2005-11-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK08456
Modules/Macros
FABJDPSN FABJDPS7 FABJDPS8 FABJDPS9
Fix information
Fixed component name
IMS HP IMAGE CO
Fixed component ID
5655K9600
Applicable component levels
R320 PSY UK08456