PK11208: S0C1 ABEND OCCURS FOLLOWING A S878-10 ABEND IN MODULE CQMOXGET

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Query Monitor may become unrepsonsive after S0C1 abend
    subsequent to a 878-10 abend in module CQMOXGET. Code has been
    corrected to not allow the S0C1 abend and continue processing.
    .
    Other Symptoms:  ABENDS0C1 ABEND878  ABENDS878  S878  RC10
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Query Monitor.                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: Query Monitor may become unrepsonsive   *
    *                      after S0C1 abend subsequent to a 878-10 *
    *                      abend in module CQMOXGET. Code has been *
    *                      corrected to not allow the S0C1 abend   *
    *                      and continue processing.                *
    *                      Other Symptoms:  ABENDS0C1   ABENDS878  *
    *                      S878  RC10                              *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK11208

  • Reported component name

    DB2 QUERY MONIT

  • Reported component ID

    5655E6701

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / CST / Xsystem

  • Submitted date

    2005-08-30

  • Closed date

    2005-09-15

  • Last modified date

    2007-06-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK07277

Modules/Macros

  •    CQMMSSQL CQMOXGET CQMOXG81
    

Fix information

  • Fixed component name

    DB2 QUERY MONIT

  • Fixed component ID

    5655E6701

Applicable component levels

  • R210 PSY UK07277

       UP05/09/30 P F509

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.