A fix is available
APAR status
Closed as program error.
Error description
HPIC abends with an S0C4, when HPIC is unable to open an input DB and HDPC=Y is specified, because HPIC does not bypass calling the HP Pointer Checker utility in such a case.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IMS High Performance Image Copy for z/OS * * Version 3 Release 2 users ( FMID=H1J0320 ) * **************************************************************** * PROBLEM DESCRIPTION: HPIC V3R2 Image Copy function * * terminates with ABEND S0C4 * * ( ABEND0C4 ) in the HPPC module * * FABPHSIX when a severe error occurs * * during the open process of an input * * database data set and HDPC=Y is * * specified in the ICEIN. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** HPIC V3R2 Image Copy function terminates with ABEND S0C4 ( ABEND0C4 ) in the HPPC module FABPHSIX when a severe error occurs during the open process of an input database data set. Because HPIC calls the termination process of HPPC without calling the initialization process of HPPC.
Problem conclusion
FABJDPSN has been modified not to call the termination process of HPPC without calling the initialization process of HPPC when a severe error occurs during the open process of an input database data set. FABJDPS7, FABJDPS8, and FABJDPS9 have been reassembled.
Temporary fix
Comments
APAR Information
APAR number
PK08786
Reported component name
IMS HP IMAGE CO
Reported component ID
5655K9600
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2005-07-13
Closed date
2005-07-19
Last modified date
2005-08-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK05529
Modules/Macros
FABJDPSN FABJDPS7 FABJDPS8 FABJDPS9
Fix information
Fixed component name
IMS HP IMAGE CO
Fixed component ID
5655K9600
Applicable component levels
R320 PSY UK05529
UP05/07/23 P F507
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.