A fix is available
APAR status
Closed as program error.
Error description
During QCF UNLOAD, ABENDS30A or different abends can occur in a rare case when moving a record into the input/output area to write it to the UNLOAD file (4 extra more bytes {x'4040'} are moved). This destroys the aligned storage therefore different errors can occur.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of QCF. In some cases a 30A- error * * may occur at end of UNLOAD procces. * **************************************************************** * PROBLEM DESCRIPTION: In some cases UNLOAD ends with error * * 30A - error on FREEMAIN call.The reason * * for this error is that 4 bytes more * * than the message's length are moved to * * the otput buffer, overlaying the * * storage that follows the output * * buffer.This happens on rear occasions , * * because of the aligning the buffer * * storage on double word boundary. * **************************************************************** * RECOMMENDATION: * **************************************************************** The program has been changed to move the exact number of bytes to the output buffer.
Problem conclusion
Problem is fixed.
Temporary fix
Comments
APAR Information
APAR number
PK07588
Reported component name
IMS QUEUE CNTL
Reported component ID
5697E9900
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2005-06-17
Closed date
2005-06-27
Last modified date
2005-07-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK04912
Modules/Macros
IQCXSUB6
Fix information
Fixed component name
IMS QUEUE CNTL
Fixed component ID
5697E9900
Applicable component levels
R210 PSY UK04912
UP05/06/29 P F506
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.