A fix is available
APAR status
-
Closed as program error.
Error description
-
The inactive datasets following OLR are listed in the Index Builder report. This could be confusing, although the correct (active) datasets are scanned to build the index. Also, the 'A' datasets are used to get the reorg number, even when these are inactive. If the 'A' datasets have been deleted, an ABENDS1708 occurs.
Local fix
Problem summary
-
**************************************************************** * USERS AFFECTED: All IMS Index Builder V2R3 HALDB users. * **************************************************************** * PROBLEM DESCRIPTION: Customer were concerened about IB V2R3 * * allocating the prime HALDB data sets in * * it's preliminary control phase. Such * * behaviour was believed to potentially * * endanger eventually ongoing IMS V9 OLR * * split. * **************************************************************** * RECOMMENDATION: * **************************************************************** IMS Index Builder V2R3, in it's preliminary control phase, is reading offline the first storage bit map block of each HALDB prime data set in order to obtain certain control data.
Problem conclusion
-
IMS Index Builder V2R3 code was changed to no more use control data obtained from any HALDB data sets. No HALDB prime data sets are allocated offline.
Temporary fix
Comments
APAR Information
-
APAR number
PK07556
-
Reported component name
IMS INDEX BUILD
-
Reported component ID
5655E2400
-
Reported release
230
-
Status
CLOSED PER
-
PE
NoPE
-
HIPER
NoHIPER
-
Special Attention
NoSpecatt / Xsystem
-
Submitted date
2005-06-17
-
Closed date
2005-07-05
-
Last modified date
2005-08-02
-
APAR is sysrouted FROM one or more of the following:
-
APAR is sysrouted TO one or more of the following:
UK05123
Modules/Macros
-
IBCD IIUBDSEC IIUBDYNA IIUBIBCD IIUBINIT IIUBLRCN IIUBMAIN IIUBPRIM IIUBPR71 IIUBPR81 IIUBPR91 IIUBUILD
Fix information
-
Fixed component name
IMS INDEX BUILD
-
Fixed component ID
5655E2400
Applicable component levels
-
R230 PSY UK05123
UP05/07/07 P F507
Fix is available
-
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89M","label":"IMS Index Builder"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.3.0"}]
Document Information
Modified date: