IBM Support

PK06258: HPIC CIC FUNCTION ABENDS WITH AN S0C4, WHEN KEYWORD HDPC=Y IS SPECIFIED IN THE ICEIN.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • HPIC CIC function abends S0C4, when HDPC=Y keyword is specified
    in the ICEIN, because HPIC does not delete some areas of IMS
    control blocks created by loading DFSRRC00 in spite of deleting
    DFSRRC00.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Image Copy for z/OS *
    *                 Version 3 Release 2 users ( FMID=H1J0320 )   *
    ****************************************************************
    * PROBLEM DESCRIPTION: This APAR fixes following problems:     *
    *                      - HPIC V3R2 Concurrent Image Copy       *
    *                        function terminates with ABEND S0C4   *
    *                        ( ABEND0C4 ) in the module DFSSBIL0   *
    *                        when HDPC=Y is specified in the       *
    *                        ICEIN and the Integrity Checker of    *
    *                        LIU is active.                        *
    *                      - HPIC V3R2 Concurrent Image Copy       *
    *                        function terminates with ABEND S112   *
    *                        ( ABEND112 ) in the module DFSSBIL0   *
    *                        when HDPC=Y is specified in the       *
    *                        ICEIN and the Integrity Checker of    *
    *                        LIU is active.                        *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    HPIC V3R2 Concurrent Image Copy function terminates with ABEND
    S0C4 in the module DFSSBIL0 when HDPC=Y is specified in the
    ICEIN and the Integrity Checker of LIU is active. Because HPIC
    does not nullify the area that is used for handling whether
    DFSPRPX0 needs to be loaded or not, although the area is filled
    by IMS DFSRRC00 calling in the initialize process of pointer
    checking. Therefore, HPIC mishandles follow-on process, and as a
    result, HPIC refers the invalid area.
    
    HPIC V3R2 Concurrent Image Copy function terminates with ABEND
    S112 in the module DFSSBIE0 when HDPC=Y is specified in the
    ICEIN and the Integrity Checker of LIU is active. Because the
    LIU Integrity checker refers the area that is loaded by the
    initialize process of pointer checking, and tries to use the
    address in DFSPRPX0 as the DCB address for BLDL macro even
    though the pointed area is already freed in the initialize
    process of pointer checking.
    

Problem conclusion

  • FABJDMPN has been modified to nullify the area that points
    DFSPRPX0 after the initialize process of pointer checking, when
    HDPC=Y is specified in HPIC Concurrent Image Copy function.
    
    FABJDMP7, FABJDMP8, and FABJDMP9 have been reassembled.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK06258

  • Reported component name

    IMS HP IMAGE CO

  • Reported component ID

    5655K9600

  • Reported release

    320

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2005-05-24

  • Closed date

    2005-06-09

  • Last modified date

    2005-07-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK04320

Modules/Macros

  • FABJDMPN FABJDMP7 FABJDMP8 FABJDMP9
    

Fix information

  • Fixed component name

    IMS HP IMAGE CO

  • Fixed component ID

    5655K9600

Applicable component levels

  • R320 PSY UK04320

       UP05/06/10 P F506

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"320","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
14 December 2020