IBM Support

PK05607: HPIC ABENDS S0C1, WHEN HDPC=O (OR BOTH OF HDPC=Y AND VIC=Y) ARE SPECIFIED IN ICEIN, AND HPIC PROCESSES INDEX DB NOT FORMATTED.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • HPIC abends S0C1, when HDPC=O or both of HDPC=Y and VIC=Y, are
    specified in the ICEIN, and HPIC processes either a primary
    index DB or a secondary index DB that is not formatted because
    HPIC does not treat the situation as an error and continues
    processing.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Image Copy for z/OS *
    *                 Version 3 Release 2 users ( FMID=H1J0320 )   *
    ****************************************************************
    * PROBLEM DESCRIPTION: HPIC V3.2 image copy function           *
    *                      terminates with ABEND S0C1 ( ABEND0C1 ) *
    *                      in the process for a primary index DB   *
    *                      or a secondary index DB that is not     *
    *                      formatted, when HDPC=O or both of       *
    *                      HDPC=Y and VIC=Y keywords are specified *
    *                      in the ICEIN.                           *
    *                                                              *
    *                      HPIC V3.2 image copy function           *
    *                      terminates with ABEND U3819             *
    *                       ( ABENDU3819 ) when the DFSMDA member  *
    *                      for Full Function DB is not provided in *
    *                      the MDA library.                        *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    HPIC V3.2 image copy function terminates with ABEND S0C1
     ( ABEND0C1 ) in the process for a primary index DB or a
    secondary index DB that is not formatted, when HDPC=O or both of
    HDPC=Y and VIC=Y keywords are specified in the ICEIN. HPIC tries
    to continue processing even though it fails in the OPEN process
    for unformatted DB. As a result, HPIC terminates with ABEND S0C1
     ( ABEND0C1 ) in the GET process after the OPEN process.
    
    HPIC V3.2 image copy function terminates with ABEND U3819
     ( ABENDU3819 ) when the DFSMDA member for Full Function DB is
    not provided in the MDA library.
    Because HPIC assumes the absence of DFSMDA member for Full
    Function DB as an inability to allocate the DB.
    

Problem conclusion

  • The macro FABJDPSN has been modified to bypass the process of
    reading a primary index DB or a secondary index DB that is not
    formatted and to issue the message DFS301A to report an error
    when HDPC=O or both of HDPC=Y and VIC=Y keywords are specified
    in the ICEIN.
    
    The module FABJMAIN has been modified to bypass the process that
    checks the existence of DFSMDA member by using BLDL macro for
    Full Function DB.
    
    The module FABJDPS7, FABJDPS8, and FABJDPS9 have been
    reassembled.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK05607

  • Reported component name

    IMS HP IMAGE CO

  • Reported component ID

    5655K9600

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2005-05-11

  • Closed date

    2005-05-25

  • Last modified date

    2005-06-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK03815

Modules/Macros

  • FABJDPSN FABJDPS7 FABJDPS8 FABJDPS9 FABJMAIN
    

Fix information

  • Fixed component name

    IMS HP IMAGE CO

  • Fixed component ID

    5655K9600

Applicable component levels

  • R320 PSY UK03815

       UP05/05/28 P F505

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.