A fix is available
APAR status
-
Closed as program error.
Error description
-
When HD Pointer Checker processes a PHIDAM database, and IXKEYCHK=YES is specified in the PROCCTL data set, HD Pointer Checker issues MSGFABP3661E and ABENDU3661.
Local fix
Problem summary
-
**************************************************************** * USERS AFFECTED: IBM IMS High Performance Pointer Checker for * * z/OS Version 2 Release 1 (FMID=HPC2210) * * users. * **************************************************************** * PROBLEM DESCRIPTION: HD Pointer Checker issues MSGFABP3661E * * and gets ABENDU3661 when PROC * * IXKEYCHK=YES is specified. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** This error occurs when all of the following conditions are satisfied: - HD Pointer Checker runs as a stand alone utility. - PROC IXKEYCHK=YES is specified to the PROCCTL data set. - A PHIDAM data base is processed and the PSINDEX data base is also specified to the DATABASE statement in the PROCCTL data set. - The index source segment of PSINDEX data base is in a dataset group (DSG) A. - An image copy of PHIDAM database is processed, or a DSG X (PHIDAM primary index) is excluded from the DATABASE statement. In these conditions, HD Pointer Checker should not check the PHIDAM primary index because of the functional restriction. But, HD Pointer Checker attempts to check the primary index incorrectly. It causes MSGFABP3661E erroneously. FABP3661E DB#: 001 PID: 00001 DSG#: A OF TA RECORD IS DIFFERENT FROM DBD
Problem conclusion
-
The module FABPLBLD did not recognize the primary index correctly. It has been changed to recognize the DBD definition of the primary index correctly.
Temporary fix
Comments
APAR Information
-
APAR number
PK05596
-
Reported component name
IMS POINTER CHE
-
Reported component ID
5655E0900
-
Reported release
210
-
Status
CLOSED PER
-
PE
NoPE
-
HIPER
NoHIPER
-
Special Attention
NoSpecatt / Xsystem
-
Submitted date
2005-05-11
-
Closed date
2005-05-18
-
Last modified date
2005-06-02
-
APAR is sysrouted FROM one or more of the following:
-
APAR is sysrouted TO one or more of the following:
UK03581
Modules/Macros
-
FABPLBLD
Fix information
-
Fixed component name
IMS POINTER CHE
-
Fixed component ID
5655E0900
Applicable component levels
-
R210 PSY UK03581
UP05/05/19 P F505
Fix is available
-
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89G","label":"IMS HP Pointer Checker"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"210"}]
Document Information
Modified date:
03 April 2021