Error description
HPIC terminates with ABEND S0C4 (ABEND0C4) because SWAREQ macro in FABJICDD does handle USB that is allocated above 16M.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IMS High Performance Image Copy for z/OS * * Version 3 Release 2 users ( FMID=H1J0320 ) * **************************************************************** * PROBLEM DESCRIPTION: HPIC Image Copy Function gets ABEND * * S0C4 ( ABEND0C4 ) when DD for output * * image copy data set that uses STACK * * function is specified on JCL. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** HPIC gets ABEND S0C4 ( ABEND0C4 ) when DD for output image copy data set that uses STACK function is specified on JCL. Because HPIC stacking function does not use LOCEPAX=YES option of IEFZB505 macro that define EPA parameter area for issuing SWAREQ macro with Read Locate mode. As the result of that garbage is set in SWQMPA (SWA control blocks) and SWAREQ process fails.
Problem conclusion
FABJICDD and FABJMDPN have been modified that: - LOCEPAX=YES option of IEFZB505 macro is defined. - Parameter area of SWAREQ is cleared with correct parameter length. FABJMDP7, FABJMDP8 and FABJMDP9 have been reassembled.
Temporary fix
Comments
APAR Information
APAR number
PK04293
Reported component name
IMS HP IMAGE CO
Reported component ID
5655K9600
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2005-04-15
Closed date
2005-04-21
Last modified date
2005-05-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK02645
Modules/Macros
FABJICDD FABJMDPN FABJMDP7 FABJMDP8 FABJMDP9
Fix information
Fixed component name
IMS HP IMAGE CO
Fixed component ID
5655K9600
Applicable component levels
R320 PSY UK02645
UP05/04/28 P F504
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"310","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
14 December 2020