Error description
When BTS Playback function BTSAISR0 runs with PL/I PSB, it does not write any DL/I call trace into BTSOUT.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: BTS V3 Users with Playback * **************************************************************** * PROBLEM DESCRIPTION: BTS Playback function (BTSAISR0) has a * * Consideration that BTS runs with only * * LANG=ASSEM/COBOL PSB. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** When BTS Playback function (BTSAISR0) runs with PL/I PSB, it does not write any DL/I call trace into BTSOUT. So when BTSAEDT0 runs with this BTSOUT, it does not put the formatted screen with BTS0004W message. It is a restriction applied to the PSB being used by Playback. BTS Playback function (BTSAISR0) is enhanced to remove the PL/I PSB restriction.
Problem conclusion
BTS is modified to run with PL/I language specified in the PSB by the LANG= keyword in addition to ASSEM or COBOL. The IMS BTS User's Guide and Reference ( SC18-7149-00 ) will be updated with following changes: Appendix E. BTS Playback: Transaction Screen Formatting Transaction Screen Formatting PSB Consideration << delete >> The language specified in the PSB by the LANG= keyword must be ASSEM or COBOL.
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
PK04070
Reported component name
IMS BTS
Reported component ID
5655A1400
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2005-04-12
Closed date
2005-05-06
Last modified date
2005-06-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK03195
Modules/Macros
BTSPC000
| SC18714900 |
Fix information
Fixed component name
IMS BTS
Fixed component ID
5655A1400
Applicable component levels
R310 PSY UK03195
UP05/05/09 P F505
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCBTY2","label":"IMS Batch Terminal Simulator"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0"}]
Document Information
Modified date:
20 October 2020