IBM Support

PK02849: ABEND0C4 IQCY0000 AT X'386' WHEN NOT UTILIZING THE NEW QCF STARTUP SCRIPT AFTER APAR PK00220

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ABENDS0C4 IQCY0000 at x'386' when not utilizing the new QCF
    startup script after APAR PK00220.  APAR PK00220 added
    a new parameter OVFLHLQ.  As part of this APAR a new startup
    script needs to be used to pass parm information.  If the old
    script is used without OVFLHLQ parm information the abend will
    occur.  We plan to put in a check to alleviate the abend,
    issue a warning message and utilize the default value.
    

Local fix

  • Run with the new startup script.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of QCF-panels.                     *
    *                 APARs PQ97787, PK00220 changed               *
    *                 QCF starting script for TSO users.           *
    *                 The script IQC is updated in installation    *
    *                 library. Users have to use the new script    *
    *                 to invoke QCF panels. A new parameter is     *
    *                 added- OVFLHLQ. It is used to build the      *
    *                 data set names with overflow protection      *
    *                 members.                                     *
    *                 When the old starting script is used-        *
    *                 a zero OVFLHLQ parameter is passed to        *
    *                 next scripts and programs .                  *
    *                 Startup program IQCY0000 abends with 0C4.    *
    ****************************************************************
    * PROBLEM DESCRIPTION: 0C4 in IQCY0000 if APARs PQ97787 and    *
    *                      PK00220 are installed, but the          *
    *                      starting IQC script is not customized   *
    *                      to pass the new parameter - OFVLHLQ.    *
    *                                                              *
    *                      The new parameter allows data sets with *
    *                      overflow protection members to have     *
    *                      different hlq, than the installation    *
    *                      QCF libraries.                          *
    *                      PQ97787 added the new parameter.        *
    *                      PK00220 made the new parameter to be    *
    *                      up to 25 bytes. MVS id , IMS id and     *
    *                      'COMMIT' / ' UNCOMMIT' are concataneted *
    *                      to OVFLHLQ to build the data sets names *
    *                      with overflow protection control card   *
    *                      members.                                *
    *                      IQC starting script sample is part of   *
    *                      both APARs. Old starting scripts        *
    *                      have to be customized according to the  *
    *                      sample- to pass the new parameter.      *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    IQCY0000 and IQCC00 are changed to set default value 'IQC' for
    starting parameter OVFLHLQ, if this parameter is not passed by
    the starting IQC script.
    

Problem conclusion

  • New starting script sample has to be used to start QCF panels.
    If old starting script is used, the OVFLHLQ parameter is set to
    default value 'IQC'.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK02849

  • Reported component name

    IMS QUEUE CNTL

  • Reported component ID

    5697E9900

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2005-03-21

  • Closed date

    2005-03-24

  • Last modified date

    2005-04-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK01795

Modules/Macros

  • IQCC00   IQCY0000
    

Fix information

  • Fixed component name

    IMS QUEUE CNTL

  • Fixed component ID

    5697E9900

Applicable component levels

  • R210 PSY UK01795

       UP05/03/28 P F503

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A6","label":"IMS Queue Control Facility"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: