A fix is available
APAR status
Closed as program error.
Error description
ABENDS0C4 IQCY0000 at x'386' when not utilizing the new QCF startup script after APAR PK00220. APAR PK00220 added a new parameter OVFLHLQ. As part of this APAR a new startup script needs to be used to pass parm information. If the old script is used without OVFLHLQ parm information the abend will occur. We plan to put in a check to alleviate the abend, issue a warning message and utilize the default value.
Local fix
Run with the new startup script.
Problem summary
**************************************************************** * USERS AFFECTED: All users of QCF-panels. * * APARs PQ97787, PK00220 changed * * QCF starting script for TSO users. * * The script IQC is updated in installation * * library. Users have to use the new script * * to invoke QCF panels. A new parameter is * * added- OVFLHLQ. It is used to build the * * data set names with overflow protection * * members. * * When the old starting script is used- * * a zero OVFLHLQ parameter is passed to * * next scripts and programs . * * Startup program IQCY0000 abends with 0C4. * **************************************************************** * PROBLEM DESCRIPTION: 0C4 in IQCY0000 if APARs PQ97787 and * * PK00220 are installed, but the * * starting IQC script is not customized * * to pass the new parameter - OFVLHLQ. * * * * The new parameter allows data sets with * * overflow protection members to have * * different hlq, than the installation * * QCF libraries. * * PQ97787 added the new parameter. * * PK00220 made the new parameter to be * * up to 25 bytes. MVS id , IMS id and * * 'COMMIT' / ' UNCOMMIT' are concataneted * * to OVFLHLQ to build the data sets names * * with overflow protection control card * * members. * * IQC starting script sample is part of * * both APARs. Old starting scripts * * have to be customized according to the * * sample- to pass the new parameter. * **************************************************************** * RECOMMENDATION: * **************************************************************** IQCY0000 and IQCC00 are changed to set default value 'IQC' for starting parameter OVFLHLQ, if this parameter is not passed by the starting IQC script.
Problem conclusion
New starting script sample has to be used to start QCF panels. If old starting script is used, the OVFLHLQ parameter is set to default value 'IQC'.
Temporary fix
Comments
APAR Information
APAR number
PK02849
Reported component name
IMS QUEUE CNTL
Reported component ID
5697E9900
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2005-03-21
Closed date
2005-03-24
Last modified date
2005-04-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK01795
Modules/Macros
IQCC00 IQCY0000
Fix information
Fixed component name
IMS QUEUE CNTL
Fixed component ID
5697E9900
Applicable component levels
R210 PSY UK01795
UP05/03/28 P F503
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A6","label":"IMS Queue Control Facility"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
01 April 2005