APAR status
Closed as unreproducible in next release.
Error description
HPFPU FPB Unload will provide a new AREC parameter on the EXEC statement for when an unloaded segment record data set does not include an area information record in the UNLOAD process. This is being provided as a result of FITS REQ MR0118054534.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All FP Basic Tools Version 1 Release 2 * * users of DEDB Unload/Reload users. * * (FMID: H1J3120) * **************************************************************** * PROBLEM DESCRIPTION: HPFPU FPB Unload provides a new AREC * * parameter on EXEC statement. * * When AREC=NO is specified, an unloaded * * segment record data set does not * * include an area information record. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** HPFPU FPB Unload (FABCUR1) provides a new AREC parameter on EXEC statement. When AREC=NO is specified, an unloaded segment record data set does not include an area information record. This enhancement is for Fits MR0118054534.
Problem conclusion
Temporary fix
Comments
HPFPU FPB Unload (FABCUR1) has been enhanced to add a new AREC parameter on the EXEC statement. AREC=Y|YES|N|NO is allowed. When AREC=Y or YES is specified, an unloaded segment record data set includes an area information record. When AREC=N or NO is specified, an unloaded segment record data set does not include an area information record. HPFPU FPB RELOAD (FABCUR3) can't process the unloaded segment record data set created with AREC=N or NO. The module FABC1GCD has been modified to set AREC parameter from the site default table or system default if AREC parameter is not specified on EXEC statement. The module FABC1INI and FABC1SB0 have been reassembled. The macro FABC1SBM has been modified as follows; When AREC=Y is specified, set AREC=Y bit (EXEFYEAC) to EXEC flag (EXEFLAGS) in order to clarify that AREC parameter is specified on EXEC statement. The macro UR1WSTG0 has been modified to introduce EXEFYEAC. The macro FABCOP1M has been modified to add a new AREC parameter. This macro generates Site Default Table. ======================== = Documentation change = ======================== IMS High Performance Fast Path Utilities for z/OS User's Guide Volume 2: Fast Path Basic Tools Version 2 Release 1 (SC18-9238-00) should be changed as follows: PART 4. DEDB Unload/Reload Utilities Chapter 13. Using the DEDB Unload Utility-FABCUR1 JCL EXEC *The following description should be changed as follows, This statement must be in the form: // EXEC PGM=FABCUR1,PARM='DBRC=x,AREC=x',REGION=rrrrK *The following description should be added to the EXEC This statement must be in the form: // EXEC PGM=FABCUR1,PARM='DBRC=x,AREC=x',REGION=rrrrK *The following description should be added to the EXEC statement explanation. AREC= Determines whether or not to include an area information record in an unloaded segment record data set. Y FABCUR1 puts an unloaded segment record data set that includes an area information record. AREC=YES also can be specified. N FABCUR1 puts an unloaded segment record data set that does not include an area information record. AREC=NO also can be specified. Default: Y
APAR Information
APAR number
PK02531
Reported component name
IMS HP FP UTILI
Reported component ID
5655K9400
Reported release
210
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2005-03-15
Closed date
2005-03-24
Last modified date
2005-04-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK01784
Modules/Macros
FABCOP1M FABC1GCD FABC1INI FABC1SBM FABC1SB0 UR1WSTG0
| SC18923800 |
Fix information
Fixed component name
IMS HP FP UTILI
Fixed component ID
5655K9400
Applicable component levels
R210 PSY UK01784
UP05/03/28 P F503
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89D","label":"IMS HP Fast Path Utilities"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"210"}]
Document Information
Modified date:
04 October 2020