IBM Support

PK01017: SELECT STEP FAILS WITH MSGIQC3054T AND JOB ENDS NORMALLY

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • SELECT step fails with IQC3054T and the job ends with RC=00.
    The job should terminate and fail with a RC=12.
    The error message received is:
    IQC3054T Checkpoint nnnnn - No End of CheckPoint Record found,
    Terminating
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: The error affects all users , that run QCF   *
    *                 to select messages to be reinserted          *
    *                 for recovery or reproccess.                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: SELECT step fails with "IQC3054T        *
    *                      Checkpoint   NNN - No End of CheckPoint *
    *                      Record  found, Terminating." The step   *
    *                      ends with RC=0, the return code is not  *
    *                      set to 12.                              *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    SELECT step ends with RC=0 when message IQC3054T is issued. The
    step terminates,the return code does not reflect the severe
    error in data( logs).
    

Problem conclusion

  • The programs are changed to preserve the RC as set in message
    generation program for this message and end the step with RC=12.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK01017

  • Reported component name

    IMS QUEUE CNTL

  • Reported component ID

    5697E9900

  • Reported release

    120

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2005-02-11

  • Closed date

    2005-02-16

  • Last modified date

    2005-03-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK00650

Modules/Macros

  •    IQCSELCT
    

Fix information

  • Fixed component name

    IMS QUEUE CNTL

  • Fixed component ID

    5697E9900

Applicable component levels

  • R120 PSY UK00650

       UP05/02/18 P F502

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.