A fix is available
APAR status
Closed as program error.
Error description
CCF jobs with /DBR command failing with ABENDS90A when CCF issues the FREEPOOL macro to free a buffer, but is incorrectly specifying a DCB address during this process.
Local fix
Change the CCF Global Option of DBRC to NODBRC, which keeps CCF from verifying the state of the database and alleviating the S90A.
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM IMS Command Control * * Facility for z/OS Version 2 Release 2 * * (FMID=H24E220) * **************************************************************** * PROBLEM DESCRIPTION: IMS Command Control Facility batch job * * that issues /DBR command terminates * * with ABENDS90A if option 3(IMS OM) is * * selected in Command Routing Technique * * Option and option 1(ABEND), * * 2(Return Code) or 3(Issue WTOR) is * * selected in IMS Command Control * * Facility Failure Option - DBRC. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** ABENDS90A or ABENDS30A may occur because of the FREEPOOL macro which specified an incorrect DCB address if you execute IMS Command Control Facility batch job which has following conditions: condition 1: 1. Option 3(IMS OM) is selected in Command Routing Technique Option of CCF IMS System Information. 2. Option 1(ABEND), 2(Return Code) or 3(Issue WTOR) is selected in IMS Command Control Facility Failure Option "DBRC" of CCF Global Options. 3. /DBD or /DBR command without ALL parameter is issued. condition 2: 1. Option 3(IMS OM) is selected in Command Routing Technique Option of CCF IMS System Information. 2. Option 2(use DBRC) is selected in IMS Command Control Facility Database Option "/START DB ACCESS" of CCF Global Options. 3. /START DB ACCESS=UP command is issued. This APAR also responds to the following problem related to FREEPOOL macro. The unnecessary buffer may not be freed and be accumulated during executing IMS Command Control Facility batch job because of the FREEPOOL macro is not issued if you execute the batch job which has following conditions: condition 1: 1. Option 1(APPC/IMS) or 2(APPC/MVS) is selected in Command Routing Technique Option of CCF IMS System Information. 2. Option 1(ABEND), 2(Return Code) or 3(Issue WTOR) is selected in IMS Command Control Facility Failure Option "DBRC" of CCF Global Options. 3. /DBD or /DBR command without ALL parameter is issued. condition 2: 1. Option 1(APPC/IMS) or 2(APPC/MVS) is selected in Command Routing Technique Option of CCF IMS System Information. 2. Option 2(use DBRC) is selected in IMS Command Control Facility Database Option "/START DB ACCESS" of CCF Global Options. 3. /START DB ACCESS=UP command is issued.
Problem conclusion
The following modules have been changed to fix the above problem: CCFIXCF0, CCFEXEC0
Temporary fix
Comments
APAR Information
APAR number
PI99234
Reported component name
IMS COMMAND CTL
Reported component ID
5655F4000
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-06-15
Closed date
2018-07-10
Last modified date
2018-10-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI57150
Modules/Macros
CCFEXEC0 CCFIXCF0
Fix information
Fixed component name
IMS COMMAND CTL
Fixed component ID
5655F4000
Applicable component levels
R220 PSY UI57150
UP18/07/13 P F807
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCBTY6","label":"IMS Command Control Facility"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2.0"}]
Document Information
Modified date:
21 October 2020