Error description
IIB calculates a CPUtime delta value for each time interval based on the difference between the CPUtime value returned by the clock() function call at the start and the end of the time interval. The C++ clock() function defines its time measurement as a type that has a maximum value of 4294967295. If a message flow thread runs long enough and consumes a large amount of CPUtime over an extended period, then the max value will be reached. When this occurs, the start and end of the time interval are the same max value, resulting in a delta CPUtime value of 0.
Local fix
Without the fix, the only way to reset the CPUtime count is to restart the process.
Problem summary
**************************************************************** USERS AFFECTED: All users of IBM Integration Bus on z/OS collecting statistics and accounting data. Platforms affected: z/OS **************************************************************** PROBLEM DESCRIPTION: IIB calculates a CPUtime delta value for each time interval based on the difference between the CPUtime value returned by the clock() function call at the start and the end of the time interval. The C++ clock() function defines its time measurement as a type that has a maximum value of 4294967295. If a message flow thread runs long enough and consumes a large amount of CPUtime over an extended period, then the max value will be reached. When this occurs, the start and end of the time interval are the same max value, resulting in a delta CPUtime value of 0. As a result, the SMF 117 IMFLTPCP field will be reported as 0.
Problem conclusion
The product has been modified so that the SMF 117 IMFLTPCP field does not zero out. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Version Maintenance Level v10.0 10.0.0.15 v11.0 11.0.0.4 The latest available maintenance can be obtained from: http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041 If the maintenance level is not yet available,information on its planned availability can be found on: http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
PI99108
Reported component name
IIB Z/OS
Reported component ID
5655AB100
Reported release
A00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-06-13
Closed date
2019-02-07
Last modified date
2019-02-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
IIB Z/OS
Fixed component ID
5655AB100
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQH8","label":"IBM Integration Bus for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
07 February 2019