APAR status
Closed as program error.
Error description
ABENDS0C4-10 in GJEIDMTD.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IMS Sysplex manager. * **************************************************************** * PROBLEM DESCRIPTION: IMS control region component of Sysplex * * Manager can fail with ABENDS0C4 in * * GJEIC61x+SUBRUOW. * **************************************************************** * RECOMMENDATION: Apply the PTF that corrects this APAR. * **************************************************************** When a user requests the information about destination queue depth on the ISPF user interface, IMS control region component of Sysplex Manager searches the scheduler message block (SMB). Since the logic for searching UOWE QTYPE is improper, ABENDS0C4 in GJEIC61x can occur with GJE2010E message.
Problem conclusion
GJEIC61x has been changed to search UOWE QTYPE in SMB properly.
Temporary fix
Comments
APAR Information
APAR number
PI98976
Reported component name
IMS SYSPLEX MGR
Reported component ID
5655P0100
Reported release
130
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-06-08
Closed date
2018-09-06
Last modified date
2019-05-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI58318
Modules/Macros
GJEG00 GJEIC61D GJEIC61E GJEIC61F GJETP210
Fix information
Fixed component name
IMS SYSPLEX MGR
Fixed component ID
5655P0100
Applicable component levels
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8AA","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.3.0"}]
Document Information
Modified date:
24 June 2022