Error description

  • The CPSM Monitor Interval for a CICSPlex is defined in the
    CPLEXDEF record for the whole CICSPlex, or in the CSYSDEF for
    the individual region. It is also specified for the individual
    CMAS when its EYUDREP file is defined, and can be specified in
    a PERIODEF.  At the region level, it inherits the interval from
    the CICSPlex.
    .
    In this scenario, the CMAS is defined to run GMT+8, the local
    LPAR is GMT+8, and the Plex is defined as:
      Monitor Interval:     1440
      Daylight saving time: No
      Timezone:             I
      Timezone offset:      0
    .
    However, the EYUMM0400I / EYUMM0401I messages to indicate a
    'Monitor resource reset' has occurred are issued unexpectedly.
    .
      EYUMM0400I I    date time applid Monitor resource reset in
      progress for Context(context) Scope(scope).
      .
      EYUMM0401I I    date time applid Monitor resource reset
      complete for Context(context) Scope(scope).
    .
    The problem is that CWPR_TIME_ZONE, CWPR_TIME_ZONE_OFFSET, and
    CWPR_DAY_LIGHT_SAVINGS did not pass the correct value from CWIN.
    .
    .
    .
    Additional Symptom(s) Search Keyword(s): KIXREVxxx
    

Local fix

  • n/a
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICSPlex SM V5R1M0, V5R2M0, V5R3M0 and   *
    *                 V5R4M0 Users                                 *
    ****************************************************************
    * PROBLEM DESCRIPTION: CPSM resets the monitor data to zeros   *
    *                      periodically based on the value of      *
    *                      monitor interval(INTVL) when the        *
    *                      CPLEXDEF record is created. The default *
    *                      monitor interval is 480 minutes.        *
    *                                                              *
    *                      If the monitor interval is set to 1440, *
    *                      the monitor data is reset every 24      *
    *                      hours, around 00:00:00 of the local     *
    *                      time. However, in some cases, the reset *
    *                      might occur at 00:00:00 UTC time.       *
    ****************************************************************
    * RECOMMENDATION: After applying the PTF that resolves this    *
    *                 APAR, all CMASes must be restarted.  Note    *
    *                 that the restarts do not need to occur at    *
    *                 the same time.                               *
    ****************************************************************
    Method CWPR (CMAS Timing Services Plex Interval Reg)
    calculates the reset time after the next interval expires
    based on the time zone of the current CICSplex.  It first
    gets the UTC time and then calculates the local time based on
    the time zone in the CICSplex.  However, method CWPR does not
    get the correct time zone set in the CICSplex resulting in an
    error in calculating the local time using UTC time.
    

Problem conclusion

  • The method CPBP(BUILD QUE OF ALL CMASPLEX) has been updated so
    that the method CWPR obtains the correct time zone setting.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI98838

  • Reported component name

    CICS TS Z/OS V5

  • Reported component ID

    5655Y0400

  • Reported release

    00M

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-06-06

  • Closed date

    2018-07-18

  • Last modified date

    2018-08-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI57323 UI57324 UI57325 UI57326

Modules/Macros

  • EYU0CPBP
    

Fix information

  • Fixed component name

    CICS TS Z/OS V5

  • Fixed component ID

    5655Y0400

Applicable component levels

  • R00M PSY UI57325

       UP18/07/19 P F807

  • R10M PSY UI57326

       UP18/07/19 P F807

  • R80M PSY UI57323

       UP18/07/19 P F807

  • R90M PSY UI57324

       UP18/07/20 P F807

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3","Edition":"","Line of Business":{"code":"","label":""}}]