Error description

  • A report is created in Cognos 10 Workspace Advanced with a
    filter applied.  The filter is created by choosing an option
    other than "Specific Values", for example the Starts With
    option.  If this report is upgraded to Cognos Analytics 11, when
    the user attempts to edit the filter in the Query, they receive
    an error:
    
    TypeError: Unable to set property 'value' of undefined or null
    reference
    
    The exact error message varies slightly depending on the user's
    browser.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    TYPEERROR WHEN EDITING FILTER IN A REPORT UPGRADED FROM COGNOS10
    WORKSPACE ADVANCED
    

Problem conclusion

Temporary fix

Comments

  • The current simplified version of filter dialog does not support
    advanced filter features. This is a product limitation we would
    like to address in a future release. For customers who need to
    use advanced filter features, please use the following
    workaround to enable the legacy filter dialog. This is a
    temporary solution until the new enhanced filter dialog is
    completed.
    Steps to enable the legacy filter dialog:
    1) Locate DefaultSettings.xml under webcontent/bi/pat (note,
    this is not in the webcontent/pat)
    2) Change
    <setting name="UseOldCustomFilterDialog" defaultValue="false"
    dataType="boolean" propType="debug" label="Use Old Filter
    Dialog"/>
    to
    <setting name="UseOldCustomFilterDialog" defaultValue="true"
    dataType="boolean" propType="debug" label="Use Old Filter
    Dialog"/>
    4) Re-Start the server.
    

APAR Information

  • APAR number

    PI98373

  • Reported component name

    COG REPORT STUD

  • Reported component ID

    5724W12RS

  • Reported release

    B0A

  • Status

    CLOSED REQ

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-05-24

  • Closed date

    2018-06-12

  • Last modified date

    2018-06-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    COGNOS ANALYTIC

  • Fixed component ID

    5724W12XX

Applicable component levels

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTSF6","label":"IBM Cognos Analytics"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B0A"}]

Document Information

Modified date:
28 February 2021