Error description

  • The process of "move to lost+found" is invoked when the
    destruction of a directory version "orphans" a file
    because it was the only directory version that gave a path to
    that file.
    
    The process involves appending 33 extra characters of unique
    identifier string to the name.
    When the name is already long (over 228 characters) that takes
    it over the maximum length of a leaf name, 260 characters.
    When this happens during the MultiSite syncreplica replay of the
    operation, syncreplica fails and the synchronization of the VOB
    family gets blocked.
    
    multitool: Warning: Object
    "demonstration_of_a_very_long_file_name_that_can_cause_a_problem
    _for_multisite_when_moved_to_lost+found_by_uncheckout.txt.keep.k
    eep.keep.keep.keep.keep.keep.keep.keep.keep.keep.keep.keep.keep.
    keep.keep.keep.keep.keep.keep.keep.keep.keep" no longer
    referenced.
    multitool: Warning: Moving object to vob lost+found directory as
    "demonstration_of_a_very_long_file_name_that_can_cause_a_problem
    _for_multisite_when_moved_to_lost+found_by_uncheckout.txt.keep.k
    eep.keep.keep.keep.keep.keep.keep.keep.keep.keep.keep.keep.keep.
    keep.keep.keep.keep.keep.keep.keep.keep.keep.bc5c47e8c35f11e699d
    e000195b51c00".
    multitool: Error: Database identifier (dbid) not found in
    database: "/sources".
    multitool: Error: Unable to replay oplog entry 4223196:
    reference to non-existent ClearCase object.
    4223196:
    op= rmver
    replica_oid= 373ac6e3.50fb11e3.b8a6.00:01:85:44:6e:12 (original)
    oplog_id= 3414961
    ...
    

Local fix

  • At the importing replica, create a new directory version
    (generally by checking out on a locally mastered branch of the
    same element)
    Merge to this new directory version
    from the directory version that the failing oplog entry is
    trying to destroy.
    
    Restart the syncreplica import. This time the destruction of the
    version will not result in "move to lost+found".
    After the packet is imported, the local directory checkout can
    be cancelled.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Users of ClearCase MultiSite.                                *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * The process of "move to lost+found" fails when path length   *
    * exceeds max length.                                          *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • A fix is available in ClearCase versions 9.0.1.9 and 9.0.2.1
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI98203

  • Reported component name

    CLRCASE MSITE W

  • Reported component ID

    5724G3200

  • Reported release

    901

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-05-21

  • Closed date

    2020-04-11

  • Last modified date

    2020-04-11

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CLRCASE MSITE W

  • Fixed component ID

    5724G3200