IBM Support

PI97704: CORRELATION DATA NOT GENERATED WHEN DEENVELOPE SERVICE IS RUN

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • After running the ITXA Deenvelope service from a business
    process, if you check the Correlations ( BP dashboard -
    Monitor - Advanced Search - Correlation) for the recently
    processed data, it is not available.
    

Local fix

  • ITXARTC - RTC61411
    SIRTC -  RTC568535
    
    TR / TR
    Circumvention: None
    

Problem summary

  • Users Affected:
    Users calling SPE (ITXA) services and expecting returned
    correlations to be persisted even when an error occurs.
    
    Problem Description:
    SPE (ITXA) Correlation is not persisted when the
    calling IBM Sterling B2B Integrator BP is set to an ERROR
    status.
    
    Platforms Affected:
    All
    

Problem conclusion

  • Resolution Summary:
    
    A code fix is provided.
    
    Added new BP parameters that allow the commit/rollback
    behavior of SPE (ITXA) and IBM Sterling B2B Integrator
    to be configurable. By adjusting this
    behavior Correlations returned by SPE (ITXA) may still be
    committed.
    By default, any correlations added/updated will be rolled-back
    if the BP status is set to ERROR.  To change this behavior set
    the BP parameter CommitDespiteError to YES.
    By default, SPE transactions are rolled-back if SPE reports an
    error status.  To change this behavior, set the BP parameter
    CommitSPEDespiteError to YES.
    
    Delivered In:
    5020603_6
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI97704

  • Reported component name

    ITX ADV

  • Reported component ID

    5724Q2301

  • Reported release

    900

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-05-09

  • Closed date

    2018-07-09

  • Last modified date

    2018-07-11

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • SPECORRL
    

Fix information

  • Fixed component name

    ITX ADV

  • Fixed component ID

    5724Q2301

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSDF7K","label":"Transformation Extender Advanced"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
15 May 2022