Fixes are available
APAR status
Closed as program error.
Error description
Its observed that generating a call to a DB2 stored procedure with a parameter of more than 2000 characters throws the following error output: IGYPG3192-E A reference-modification length value caused reference to be made beyond the rightmost character of "EZELNK-MEMWORK0". A reference extending to the end of "EZELNK-MEMWORK0" was assumed.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * It is possible to get a compiler error from cobol * * complaining about the size of EZELNK-MEMORK type variables, * * if the SQL prepare size is greater than the default area. * **************************************************************** * PROBLEM DESCRIPTION: * * The symbolic parameter WORKFIELDLENGTh should be used, as * * documented, to increase the size of the SQL prepare area, * * however, it is possible that a compiler error can still * * happen. The symparm was not adjusting the size of * * EZELNK-MEMWORK type variables, when it should have been. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
The symparm now adjusts the minimum size of these EZELNK-MEMWORK type variables, which will fix the compiler error.
Temporary fix
Comments
APAR Information
APAR number
PI97386
Reported component name
RATL BUS DEV
Reported component ID
5724S5000
Reported release
950
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-04-30
Closed date
2019-01-18
Last modified date
2019-01-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL BUS DEV
Fixed component ID
5724S5000
Applicable component levels
R911 PSY
UP
R950 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"950","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
18 October 2021