Error description

  • ABEND0C4 can occur in CSECT FABPSTMS at offset X'2DC' under the
    following conditions:
    - HDPC is run as a stand-alone job.
    - The END statement is specified in the PROCCTL data sets.
    
    SYSTEM COMPLETION CODE=0C4  REASON CODE=00000004
       DATA AT PSW  002E1892 - 06E0956B  E0004770  C39645E0
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: IBM IMS High Performance Pointer Checker for *
    *                 z/OS Version 3 Release 1 (FMID=HPC2310)      *
    *                 users who run HD Pointer Checker(HDPC) and   *
    *                 Space Monitor(SPMN)                          *
    ****************************************************************
    * PROBLEM DESCRIPTION: HPPC gets ABEND0C4 in CSECT FABPSTMS    *
    *                      at offset X'2DC'.                       *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    ABEND0C4 can occur in CSECT FABPSTMS at offset X'2DC'
     SYSTEM COMPLETION CODE=0C4 REASON CODE=00000004
      DATA AT PSW 002E1892 - 06E0956B E0004770 C39645E0
    under either of the following conditions:
    - HDPC is run when PROC, OPTION, REPORT, DATABASE, or END
      statement with no keywords is specified in the PROCCTL data
      set.
    - SPMN or SPMN Site Default Generation utility is run when
      PROC, OPTION, DATABASE, or END statement with no keywords is
      specified in the FABKCTL data set.
    
    In these cases, when HPPC analyzes control statements, HPPC can
    incorrectly refers to an inaccessible area that was located
    before the area getmained for control statement analysis.
    

Problem conclusion

  • HPPC has modified to fix the error.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI96525

  • Reported component name

    IMS POINTER CHE

  • Reported component ID

    5655E0900

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-04-12

  • Closed date

    2018-04-25

  • Last modified date

    2018-05-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI55432

Modules/Macros

  • FABPSTMS
    

Fix information

  • Fixed component name

    IMS POINTER CHE

  • Fixed component ID

    5655E0900

Applicable component levels

  • R310 PSY UI55432

       UP18/04/26 P F804

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89G","label":"IMS Tools"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"3.1.0"}]

Document Information

Modified date:
08 June 2023