PI96085: AFTER EXPAND TO THE LOWEST MEMBER, THE MEMBERS BELOW ARE INDENTED UNEXPECTEDLY.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as fixed if next.

Error description

  • After expand to the lowest member, the members below are
    indented unexpectedly. Although the issue was resolved by
    changing 'Indentation type' from 'None' to 'Based on the level
    in the hierarchy', it should work as default.
    

Local fix

  • Set  'Level indentation' properties as the following steps.
    - Select 'Level indentation' for the item.
    - Change 'Indentation type' from 'None' to 'Based on the level
    in the hierarchy' .
    - Set '1' as 'Indent towards the right' .
    - Select 'OK'.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All Users                                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See Error Description                                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Upgrade to IBM Cognos Analytics 11.1.2                       *
    ****************************************************************
    

Problem conclusion

Temporary fix

Comments

  • We have given the user the ability to change the default system
    wide.
    A new entry was added to the DefaultSettings.xml file (shown
    below)
    
        <setting name="CrosstabIndentationBehavior" label="Crosstab
    indentation behavior" defaultValue="relative" dataType="enum">
            <enumValues>
                <enumValue value="relative" label="Relative"/>
                <enumValue value="level" label="Based on the level
    in the hierarchy"/>
            </enumValues>
        </setting>
    
    The default value for this setting is "relative".  If the users
    changes it to "level", the default from that point on will
    be level.
    
    Things to note
        1) A server restart may be required.
        2) The user's browser cache may need to be flushed.
        3) If the default value is any other then "level" (For
    example "Level", or "LEVEL"), then the software assumes
    "relative"
    

APAR Information

  • APAR number

    PI96085

  • Reported component name

    COG REPORT STUD

  • Reported component ID

    5724W12RS

  • Reported release

    B0A

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-04-02

  • Closed date

    2020-03-20

  • Last modified date

    2020-03-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCHNWW","label":"Report Authoring v11x"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B0A","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
20 March 2020