A fix is available
APAR status
Closed as program error.
Error description
In IDAA environments only with CDC z/OS PTF UI53200 applied, if a desynchronizing database utility is run against an actively mirrored table and the source has the standard IDAA setting ONUNTILITYACTION=IDLE, then the subscription might end abnormally with a dump immediately after it was idled. The following event log messages are generated, CHC0742I Table <tablename> in subscription <subname> has been set to status IDLE by <subname> CHC0330E An internal error was detected, Task(SDT), Module(CHCSDTPF), MaintLvl(PI79094), Line(1935), an SVC Dump will be requested
Local fix
If the problem occurs, the subscription can be restarted. To avoid the issue, idle all mirrored tables that are affected by the database utility prior to running the utility and then resynchronize the tables.
Problem summary
**************************************************************** * USERS AFFECTED: IDAA users of InfoSphere Change Data * * Capture for z/OS. * **************************************************************** * PROBLEM DESCRIPTION: In IDAA environments only with CDC z/OS * * PTF UI53200 applied, if a * * desynchronizing database utility is run * * against an actively mirrored table and * * the source has the standard IDAA * * setting ONUNTILITYACTION=IDLE, then the * * subscription might end abnormally with * * a dump immediately after the table was * * idled. The following event log messages * * are generated, * * * * CHC0742I Table <tablename> in * * subscription <subname> has been set to * * status IDLE by <subname> * * * * CHC0330E An internal error was * * detected, Task(SDT), Module(CHCSDTPF), * * MaintLvl(PI79094), Line(1935), an SVC * * Dump will be requested * **************************************************************** * RECOMMENDATION: APPLY CORRECTIVE SERVICE * **************************************************************** The code in PTF UI53200 that notifies the target of the table's state change to idle when a database utility was run did not properly initialize the interval variables that identify the table.
Problem conclusion
The notification code was updated to track the idled table correctly.
Temporary fix
Comments
APAR Information
APAR number
PI96006
Reported component name
INFO SRVR CDC Z
Reported component ID
5655U7600
Reported release
A21
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-03-30
Closed date
2018-04-13
Last modified date
2018-05-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI55213
Modules/Macros
CHCDLSGP
Fix information
Fixed component name
INFO SRVR CDC Z
Fixed component ID
5655U7600
Applicable component levels
RA21 PSY UI55213
UP18/04/19 P F804
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTVMA","label":"InfoSphere Data Replication for DB2 for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.2.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.2.1","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
01 May 2018