A fix is available
APAR status
Closed as program error.
Error description
IZTGEN generates incorrect WFI parameter for the TRANSACT macro
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: All IBM IMS Extended Terminal Option Support * * for z/OS Version 3 Release 2 (FMID=H1J4320) * * users. * **************************************************************** * PROBLEM DESCRIPTION: IZTGEN generates incorrect WFI * * parameter for the TRANSACT macro * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** When the WFI parameter for the TRANSACT macro is specified in existing IMS Sysgen source, the IZTGEN process recreates IMS Sysgen source that contains incorrect WFI parameter "PARM=WFI". If STAGE1 is run using the IMS Sysgen source, it fails with the error message "G302 POSITIONAL PARAMETER(S)INVALID." The reason of the error is that IZTGEN macro provided by IMS ETO Support contains a wrong code.
Problem conclusion
IZTGEN macro has been modified to generate WFI parameter as the only positional parameter for the TRANSACT macro.
Temporary fix
Comments
APAR Information
APAR number
PI95957
Reported component name
IMS ETO SUPPORT
Reported component ID
5655E1200
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-03-29
Closed date
2018-04-19
Last modified date
2018-05-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI55318
Modules/Macros
IZTGEN
Fix information
Fixed component name
IMS ETO SUPPORT
Fixed component ID
5655E1200
Applicable component levels
R320 PSY UI55318
UP18/04/21 P F804
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX897","label":"IMS ETO Support"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"320"}]
Document Information
Modified date:
04 October 2020