A fix is available
APAR status
Closed as program error.
Error description
A timing issue on an ECB that is not posted after initialization completes.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: All DRF/XF v2.1 Users * **************************************************************** * PROBLEM DESCRIPTION: IMS HEALTH CHECK GOES INTO A WAIT * **************************************************************** * RECOMMENDATION: Apply corrective maintenance for PI95353 * **************************************************************** Previous APAR corrected a problem on a ECB being double posted, by bypassing the POST when ECB has been posted. This resulted in a hang situation in certain conditions. This APAR corrects the hang
Problem conclusion
Logic to bypass a posted ECB is removed and ECB is cleared before the wait.
Temporary fix
Comments
APAR Information
APAR number
PI95353
Reported component name
IMS RCVR SOLUTN
Reported component ID
5655V8600
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-03-19
Closed date
2018-05-16
Last modified date
2018-06-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI55885
Modules/Macros
IROMIPRC IROMSREM
Fix information
Fixed component name
IMS RCVR SOLUTN
Fixed component ID
5655V8600
Applicable component levels
R210 PSY UI55885