A fix is available
APAR status
Closed as program error.
Error description
IBM Tools Base Generic Logger Exit loop causing IMS Control Region S0C4 abend during startup. This is the forward fit of APAR PI94128.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: All users of IMS Tools Base v1.6. * **************************************************************** * PROBLEM DESCRIPTION: Generic Exits creates internal table * * for user exits and calls them one after * * the other on IMS call to the exit. In * * the internal table IMS registers are * * preserved, but the first word of the * * save area is not set to x'80', as it * * should. * * * * If the exit is iWAITed and then posted * * on termination, IMS post program * * DFSIPOST abends with S0C4 while looping * * to find save area with x'80' in the * * first word. * **************************************************************** * RECOMMENDATION: * **************************************************************** Generic Exit does not set correct IMS back save area and DFSIPOST abends on IMS termination
Problem conclusion
Install this PTF to avoid IMS abend S0C4 on termination.
Temporary fix
Comments
APAR Information
APAR number
PI95275
Reported component name
TOOLS BASE
Reported component ID
5655V9300
Reported release
160
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-03-15
Closed date
2018-06-12
Last modified date
2018-07-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI56466
Modules/Macros
GLXIINTD GLXIINTE GLXIINTF GLXILGXD GLXILGXE GLXILGXF
Fix information
Fixed component name
TOOLS BASE
Fixed component ID
5655V9300
Applicable component levels
R160 PSY UI56466
UP18/06/21 P F806
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.