A fix is available
APAR status
Closed as program error.
Error description
Customer uses SETXCF command to move ( rebuild ) OSAM structure. There are several DL/I Batch jobs running in datasharing mode and connected to the structure. The single TCB design of DL/I Batch and the nature of these applications prevented DFSCST00 in the batch jobs from being dispatch to respond to REBUILD QUIESCE, so Rebuild is delayed. During this time an online IMS abends and is restarted. Before it failed it responded to REBUILD QUIESCE. At restart it issues IXLCONN to reconnect to the structure. This succeeds but CONAFLAGS,CONAREBUILD is returned. In this path the CONNECT token is not saved. Later IXLDISC is attempted, but gets RC08 RSN 0204080A since token is bad. DFS3383E STOP DATA SHARING FAILED, DATA=60 00000008 0204080A CONNECTOR NAME: IXCLO00C0001 CFNAME: WCF1A ADDITIONAL STATUS INFORMATION: REBUILD IS IN PROGRESS Since IMS remains connected, but is unable to process REBUILD events, the REBUILD remains hung and entire datasharing group is impacted until this IMS is recycled. DFSDMAW0 needs to save the connection token in this path so the IXLDISC will work.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: IMS V13 OSAM or VSAM coupling facility * * structure users * **************************************************************** * PROBLEM DESCRIPTION: IMS OSAM or VSAM structure rebuild * * hangs when IMS connects during * * structure rebuild and disconnects * * from rebuild using an invalid * * connect token. This failed disconnect * * from the structure rebuild causes the * * rebuild to hang. * * Additional symptom: ABENDS026 * **************************************************************** * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** When IMS is restarted and attempts to connect to OSAM or VSAM structure, and the structure is currently being rebuilt, the connection succeeds. Since IMS does not support processing a partial sequence of rebuild events, it would disconnect from the structure being rebuilt. Unfortunately, the connect token is not saved in this case and the disconnect from the structure fails. Since the connection remains, the structure rebuild cannot proceed without event response from this IMS. This IMS would not respond to the rebuild event because it is not aware that it is still connected to the structure. The structure rebuild hangs. ----- Additional symptom: ABENDS026 REASON=08118001
Problem conclusion
GEN: KEYWORDS: SYSPLEXDS *** END IMS KEYWORDS *** Module DFSDMAW0 has been modified to resolve the rebuild hang problem. When an OSAM or VSAM structure rebuild occurs at IMS structure connect time, it would save the connect token returned for subsequent structure disconnect from the structure being rebuilt.
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
PI94821
Reported component name
IMS V13
Reported component ID
5635A0400
Reported release
300
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-03-07
Closed date
2018-03-29
Last modified date
2018-05-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
DFSDMAW0
Fix information
Fixed component name
IMS V13
Fixed component ID
5635A0400
Applicable component levels
R300 PSY UI54867
UP18/04/04 P F804
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"300","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: