IBM Support

PI94821: IMS RESTARTING WHEN OSAM CF STRUCTURE IS BEING REBUILT FAILS TO DISCONNECT FROM THE STRUCTURE, WHICH BLOCKS THE REBUILD

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Customer uses SETXCF command to move ( rebuild ) OSAM
    structure.
    There are several DL/I Batch jobs running in datasharing mode
    and connected to the structure. The single TCB design of DL/I
    Batch and the nature of these applications prevented DFSCST00
    in the batch jobs from being dispatch to respond to REBUILD
    QUIESCE, so Rebuild is delayed.
    During this time an online IMS abends and is restarted.
    Before it failed it responded to REBUILD QUIESCE.
    At restart it issues IXLCONN to reconnect to the structure.
    This succeeds but CONAFLAGS,CONAREBUILD is returned.
    In this path the CONNECT token is not saved.
    Later IXLDISC is attempted, but gets RC08 RSN 0204080A
    since token is bad.
    DFS3383E STOP DATA SHARING FAILED, DATA=60 00000008 0204080A
    CONNECTOR NAME: IXCLO00C0001 CFNAME: WCF1A
    ADDITIONAL STATUS INFORMATION:
     REBUILD IS IN PROGRESS
    Since IMS remains connected, but is unable to process REBUILD
    events, the REBUILD remains hung and entire datasharing group
    is impacted until this IMS is recycled.
    DFSDMAW0 needs to save the connection token in this path so
    the IXLDISC will work.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: IMS V13 OSAM or VSAM coupling facility       *
    *                 structure users                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: IMS OSAM or VSAM structure rebuild      *
    *                      hangs when IMS connects during          *
    *                      structure rebuild and disconnects       *
    *                      from rebuild using an invalid           *
    *                      connect token.  This failed disconnect  *
    *                      from the structure rebuild causes the   *
    *                      rebuild to hang.                        *
    *                      Additional symptom: ABENDS026           *
    ****************************************************************
    * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF      *
    ****************************************************************
    When IMS is restarted and attempts to connect to OSAM or
    VSAM structure, and the structure is currently being rebuilt,
    the connection succeeds.  Since IMS does not support
    processing a partial sequence of rebuild events, it would
    disconnect from the structure being rebuilt.  Unfortunately,
    the connect token is not saved in this case and the
    disconnect from the structure fails. Since the connection
    remains, the structure rebuild cannot proceed without event
    response from this IMS. This IMS would not respond to the
    rebuild event because it is not aware that it is still
    connected to the structure.  The structure rebuild hangs.
    -----
    Additional symptom: ABENDS026 REASON=08118001
    

Problem conclusion

  • GEN:
    KEYWORDS:
     SYSPLEXDS
    
    *** END IMS KEYWORDS ***
    Module DFSDMAW0 has been modified to resolve the rebuild
    hang problem.  When an OSAM or VSAM  structure rebuild occurs
    at IMS structure connect time, it would save the connect token
    returned for subsequent structure disconnect from the structure
    being rebuilt.
    

Temporary fix

  • *********
    * HIPER *
    *********
    

Comments

APAR Information

  • APAR number

    PI94821

  • Reported component name

    IMS V13

  • Reported component ID

    5635A0400

  • Reported release

    300

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-03-07

  • Closed date

    2018-03-29

  • Last modified date

    2018-05-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PI94891 PI95251 UI54867

Modules/Macros

  •    DFSDMAW0
    

Fix information

  • Fixed component name

    IMS V13

  • Fixed component ID

    5635A0400

Applicable component levels

  • R300 PSY UI54867

       UP18/04/04 P F804 Ž

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"300","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
14 December 2020