APAR status
Closed as program error.
Error description
Skip to next data set if the requested one can not be opened.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IMS Sysplex manager. * **************************************************************** * PROBLEM DESCRIPTION: The IMS Sysplex Manager server address * * space can abend U0001-00000061 with * * IEC161I 052(009,jobname) message. * **************************************************************** * RECOMMENDATION: Apply the PTF that corrects this APAR. * **************************************************************** When a history data se is full, Sysplex Manager server switches to the next history data set. At this time, if a history archiving program or a history monitoring program is using the next history data set, it cannot be opened for reuse. In this case, Sysplex Manager server abends U0001-00000061.
Problem conclusion
Sysplex Manager server has been changed as follows: When Sysplex Manager server cannot switch to the next history data set due to OPEN error, IMS Sysplex Manager server waits for three seconds and tries to open the history data set again. The retry continues up to 10 times until the data set opens. If the retry fails for the 10th time, the IMS Sysplex Manager server abends U0001-00000061.
Temporary fix
Comments
APAR Information
APAR number
PI94118
Reported component name
IMS SYSPLEX MGR
Reported component ID
5655P0100
Reported release
130
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-02-21
Closed date
2018-09-04
Last modified date
2018-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI58283
Modules/Macros
GJEHYDU
Fix information
Fixed component name
IMS SYSPLEX MGR
Fixed component ID
5655P0100
Applicable component levels
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8AA","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.3.0"}]