Fixes are available
9.0.0.7: WebSphere Application Server traditional V9.0 Fix Pack 7
9.0.0.8: WebSphere Application Server traditional V9.0 Fix Pack 8
9.0.0.9: WebSphere Application Server traditional V9.0 Fix Pack 9
9.0.0.10: WebSphere Application Server traditional V9.0 Fix Pack 10
9.0.0.11: WebSphere Application Server traditional V9.0 Fix Pack 11
9.0.5.0: WebSphere Application Server traditional Version 9.0.5 Refresh Pack
9.0.5.1: WebSphere Application Server traditional Version 9.0.5 Fix Pack 1
9.0.5.2: WebSphere Application Server traditional Version 9.0.5 Fix Pack 2
9.0.5.3: WebSphere Application Server traditional Version 9.0.5 Fix Pack 3
9.0.5.4: WebSphere Application Server traditional Version 9.0.5 Fix Pack 4
9.0.5.5: WebSphere Application Server traditional Version 9.0.5 Fix Pack 5
WebSphere Application Server traditional 9.0.5.6
9.0.5.7: WebSphere Application Server traditional Version 9.0.5 Fix Pack 7
9.0.5.8: WebSphere Application Server traditional Version 9.0.5.8
9.0.5.9: WebSphere Application Server traditional Version 9.0.5.9
9.0.5.10: WebSphere Application Server traditional Version 9.0.5.10
9.0.5.11: WebSphere Application Server traditional Version 9.0.5.11
APAR status
Closed as program error.
Error description
Cannot start ODR server after being created on plinux due on incorrect version of HeapDetect setting.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM WebSphere Application * * Server WAS ND edition- Virtual * * Enterprise/IM Component * **************************************************************** * PROBLEM DESCRIPTION: ODR server cannot be started after * * being created on plinux due on * * incorrect version of HeapDetect * * setting * **************************************************************** * RECOMMENDATION: * **************************************************************** Cannot start ODR server after being created on plinux due on incorrect version of HeapDetect setting.
Problem conclusion
There is an error in detecting the 64 bit plinux operating system and results into this incorrect HeapDetect setting. With the fix of this APAR the setting on plinux will be set correctly and an ODR server should be able to be started after creation. The fix for this APAR is currently targeted for inclusion in fix pack 9.0.0.7. Please refer to the Recommended Updates page for delivery information: http://www.ibm.com/support/docview.wss?rs=180&uid=swg27004980
Temporary fix
In the server.xml of the ODR server, search for agentlib=HeapDetect text. Update HeapDetect to HeapDetect64, then start the ODR server.
Comments
APAR Information
APAR number
PI93376
Reported component name
WEBS APP SERV N
Reported component ID
5724H8800
Reported release
900
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-02-05
Closed date
2018-02-13
Last modified date
2018-03-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBS APP SERV N
Fixed component ID
5724H8800
Applicable component levels
R900 PSY
UP
Document Information
Modified date:
04 May 2022