A fix is available
APAR status
Closed as program error.
Error description
TestConductor continues build process also in case of warnings and errors when updating TestPackage. Since TestConductor is ignoring warnings and errors when updating TestPackage, the test application can be built and executed, and the test can be successfully passed, although in reality not the specified test is executed. To reproduce this you can create a SD TestCase, in which a message from SuT to the TestComponent is modeled, which has a wrong name. You will get a warning that will be ignored, like: WARNING: 'SD_tc_0': Message 'message_0', received by instance line 'TCon_SuT.itsTestCompStateChart', has been ignored. For testing of safety critical software this behavior is not acceptable, because the tests are not reliable in that case. In such a situation the build of the test shall be interrupted and cancelled. A possible solution could be a configurable error and warning assessment.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Rhapsody * **************************************************************** * PROBLEM DESCRIPTION: * * TestConductor continues build process also in case of * * warnings and errors * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
TestConductor behavior is: If there is an error, updating the test code is aborted and the test application is not built and the test is not executed. If there is a warning then test code is updated and the test can be built and executed. Providing an option to abort also in case of warnings is a feature request.
Temporary fix
Comments
APAR Information
APAR number
PI93095
Reported component name
TLOGIC RHAPSODY
Reported component ID
5724V74RP
Reported release
830
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-01-30
Closed date
2018-06-17
Last modified date
2018-06-17
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC RHAPSODY
Fixed component ID
5724V74RP
Applicable component levels
R830 PSY
UP