Fixes are available
APAR status
Closed as program error.
Error description
If a test ends with 2 Assert actions and the last one is disabled, test passes even if the enabled Assert action fails. If you move the disabled Assert action above the enabled one, the test will fail as expected. Steps to reproduce: 1. Create a new test. 2. Add a failing Assert action with the following script: eq(1, 2) 3. Add an Assert after the first one with the following script: eq(2, 2) 4. Save and run the test. Expected result: The test should fail and shows the Assert action failing in the console. Actual result: The test passes and shows the Assert action failing in the console.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of Rational Integration Tester with multiple assert * * actions in a single test. * **************************************************************** * PROBLEM DESCRIPTION: * * Rational Integration Tester treats consecutive Assert * * actions as a single group. If an Assert fails, the test * * continues to run until the final assertion in the group was * * performed. If the final Assert in the group was disabled, it * * was possible for the test to pass incorrectly. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
Rational Integration Tester 9.2.0 now correctly processes multiple assert actions correctly.
Temporary fix
Comments
APAR Information
APAR number
PI92987
Reported component name
RATL INTEGRA TE
Reported component ID
5725G79IT
Reported release
910
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-01-26
Closed date
2018-04-23
Last modified date
2018-04-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL INTEGRA TE
Fixed component ID
5725G79IT
Applicable component levels
R800 PSN
UP
R801 PSN
UP
R850 PSN
UP
R851 PSN
UP
R860 PSN
UP
R870 PSN
UP
R871 PSN
UP
R900 PSN
UP
R901 PSN
UP
R910 PSN
UP
R911 PSN
UP
R920 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSBLQQ","label":"Rational Test Workbench"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"910","Line of Business":{"code":"LOB45","label":"Automation"}}]