IBM Support

PI92587: SNAPSHOT HISTORY DATA IS TRUNCATED

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • SNAPSHOT history data is being collected and is visbile in the
    PE client up to a point in time. After that time no further
    SNAPSHOT history data is visible. The point in time generally
    coincides with the DB2 subsystem(s) being monitored experiencing
    a significant increase in activity.
    
    The DB2 subsystem is returning a reason code of 00E60802 which
    indicates that the return area provided by OMPE is not large
    enough for the amount of data being returned.
    
    Code will be changed to handle the 00E60802 reason code in a
    better fashion.
    

Local fix

  • reduce the amount of data being collected for Sanpshot history
    In the RKD2PAR(OMPEdbid) members determine if all of the
    following are needed
    SHSTATISTICS=(Y,120)
    SHSQLCACHE=(Y,300)
    SHDATASETSTATISTICS=(Y,300)
    SHSYSTEMPARAMETERS=(Y,300)
    SHTHREAD=(Y,60)
    SHTHREADLOCK=Y
    SHTHREADSQL=Y
    SHDB2CONNECTAPPLICATION=(Y,60)
    SHDB2CONNECTSYSTEM=(Y,120)
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2 PM                *
    *                 users of component                           *
    *                        -  Performance Expert Client          *
    *                        -  PE Server subtask                  *
    *                                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: The Performance Expert Client does not  *
    *                      show snapshot history data in case      *
    *                      there is a large volume of active       *
    *                      threads and the parameter to collect    *
    *                      CPU parallelism data is set to 'NO'     *
    *                      (COLLECTCPUPARALLEL=N).                 *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    The problem surfaces when the following condition is true:
    The IFI reason code on a READS call that returns a warning
    (RC=4) is not equal to 00E60804 (for example 00E60802 or
    00E6080A) AND the OMPE Collector parameter COLLECTCPUPARALLEL=N.
    
    In this situation no data is written to the Snapshot History
    dataset and thus no data is displayed in the PE Client.
    
    Note that this situation is applicable not only for thread data,
    but can be observed also if the customer has turned on snapshot
    history collection for Dynamic Statement Cache data
    (SHSQLCACHE=(Y,x) in rHilev.RKD2PAR).
    

Problem conclusion

  • The code logic has been corrected to accept all IFI reason codes
    that indicate data truncation to be processed correctly by the
    snapshot history data collector code.
    
    Furthermore, the product tracing has been enhanced with new
    tracing messages that are enabled when the trace level of the PE
    Server is set to TL=128.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI92587

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    530

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-01-17

  • Closed date

    2018-03-30

  • Last modified date

    2018-04-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI54882 UI54883

Modules/Macros

  •    DGOVHM00 DGOVMSTR FPEVDIM
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R530 PSY UI54882

       UP18/04/02 P F803

  • R540 PSY UI54883

       UP18/04/02 P F803

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: