IBM Support

PI92558: ENABLE THE MAXLOGS RC PARAMETER FOR 2 STEP BATCH AND ISPF MODES.FORWARD-FIT OF PI50878

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • Enable the MAXLOGS RC parameter for 2 step batch and ISPF modes.
    Forward-fit of PI50878.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IBM IMS High Performance Change          *
    *                 Accumulation Utility users.                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: No default MAXLOGS RC/MAXLGRC is set if *
    *                      the MAXIMUM LOGS=/MAXLOGS= parameters   *
    *                      are used but MAXLOGS RC/MAXLGRC are     *
    *                      omitted.                                *
    *                      Un-predictable errors or AbEnds can     *
    *                      occur if the //SYSPRINT DD is omitted.  *
    ****************************************************************
    * RECOMMENDATION: APPLY PTF for APAR PI92558.                  *
    ****************************************************************
    HPCABAT0 does not ensure a MAXLOG RC value.  This leads to the
    job finishing with RC=0 and no HPC1310I message is issued even
    though the MAXIMUM LOGS threshold is met.
    HPCSBAT0 omits the syntax and use/meaning of MAXLGRC and this is
    not intuitive.
    When SYSPRINT DD is omitted HPCABAT0 dynamically allocates the
    SYSPRINT dataset.  The allocation parameters used in the SVC 99
    specify and incorrect block size.  The HPCABATO establishes the
    DCBEODA & DCBSYNA in the DSB based on register 4 which points to
    the DSB at the time it is built.  HPCALST0 later opens SYSPRINT
    for input and accesses the DSB with register 7.  EOD or I/O
    error conditions result in un-predictable AbEnds.
    

Problem conclusion

Temporary fix

Comments

  • HPCABAT0 is changed to check for parameter MAXLOG
    RC=nn/MAXLGRC=nn if parameter MAXIMUM LOGS=nnn/MAXLOGS=nnn is
    specified.  If MAXIMUM LOGS=nnn/MAXLOGS=nnn is specified but
    MAXLOG RC=nn/MAXLGRC=nn is omitted, then default return code
    value 1 is set for MAXLOG RC=nn/MAXLGRC=nn.
    
    HPCSBAT0 in SHPCSAMP is updated to show the syntax and meaning
    of the MAXLGRC parameter.
    
    HPCAMAIN is changed to output the correct RC with the
    MAXLOGS/MAXLOG RC conditions are met.
    
    HPCABAT0 is changed to allocate SYSPRINT with an appropriate
    block size.
    
    HPCALST0 is changed to reference the SYSPRINT DSB with the
    correct register.
    

APAR Information

  • APAR number

    PI92558

  • Reported component name

    IMS RCVR SOLUTN

  • Reported component ID

    5655V8600

  • Reported release

    210

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / Xsystem

  • Submitted date

    2018-01-17

  • Closed date

    2018-02-12

  • Last modified date

    2018-06-11

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI53801

Modules/Macros

  • HPCABAT0 HPCALST0 HPCAMAIN HPCITKB  HPCSBAT0
    

Publications Referenced
SC27844300    

Fix information

  • Fixed component name

    IMS RCVR SOLUTN

  • Fixed component ID

    5655V8600

Applicable component levels

  • R210 PSY UI53801

       UP18/02/16 P F802

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: