IBM Support

PI92153: Provide a more detailed description when IDBA string is not present in an input module.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Provide a more detailed description when IDBA string is not
    present in an input module
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of the IBM Automatic Binary        *
    *                 Optimizer (ABO) for z/OS, v1.3.              *
    ****************************************************************
    * PROBLEM DESCRIPTION: If an input module is modified after it *
    *                      was generated by the compiler, ABO may  *
    *                      skip optimizing the CSECT and produce   *
    *                      the message "BOZ4101: No applicable     *
    *                      COBOL code section found".  This may    *
    *                      be due to ABO not being able to find    *
    *                      an eyecatcher (the string "IDBA") in    *
    *                      the module.                             *
    *                                                              *
    *                      This APAR improves ABO to produce an    *
    *                      additional message. BOZ1455:            *
    *                      unsupported feature "missing IDBA       *
    *                      string" found, in such cases.           *
    ****************************************************************
    * RECOMMENDATION: Apply provided service                       *
    ****************************************************************
    ABO was enhanced to produce a more detailed message about the
    missing IDBA string.
    

Problem conclusion

  • ABO now produces a more detailed message if the IDBA string is
    not present in the input module.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI92153

  • Reported component name

    AUTO BINARY OPT

  • Reported component ID

    5697AB100

  • Reported release

    130

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-01-08

  • Closed date

    2018-02-22

  • Last modified date

    2018-03-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI54012 UI54013

Modules/Macros

  • BOZBXITA BOZEXE1  BOZJIVP  BOZMSGE  BOZMSGK  BOZMSGT  BOZOBJ1
    BOZOPT   BOZRIDT  BOZSRC1
    

Fix information

  • Fixed component name

    AUTO BINARY OPT

  • Fixed component ID

    5697AB100

Applicable component levels

  • R130 PSY UI54012

       UP18/03/01 P F802

  • R13J PSY UI54013

       UP18/03/01 P F802

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSERQD","label":"IBM Automatic Binary Optimizer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"130","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"130","Edition":"","Line of Business":{"code":"","label":""}}]