Fixes are available
9.0.0.8: WebSphere Application Server traditional V9.0 Fix Pack 8
9.0.0.9: WebSphere Application Server traditional V9.0 Fix Pack 9
9.0.0.10: WebSphere Application Server traditional V9.0 Fix Pack 10
9.0.0.11: WebSphere Application Server traditional V9.0 Fix Pack 11
9.0.5.0: WebSphere Application Server traditional Version 9.0.5 Refresh Pack
9.0.5.1: WebSphere Application Server traditional Version 9.0.5 Fix Pack 1
9.0.5.2: WebSphere Application Server traditional Version 9.0.5 Fix Pack 2
9.0.5.3: WebSphere Application Server traditional Version 9.0.5 Fix Pack 3
9.0.5.4: WebSphere Application Server traditional Version 9.0.5 Fix Pack 4
9.0.5.5: WebSphere Application Server traditional Version 9.0.5 Fix Pack 5
WebSphere Application Server traditional 9.0.5.6
9.0.5.7: WebSphere Application Server traditional Version 9.0.5 Fix Pack 7
9.0.5.8: WebSphere Application Server traditional Version 9.0.5.8
9.0.5.9: WebSphere Application Server traditional Version 9.0.5.9
9.0.5.10: WebSphere Application Server traditional Version 9.0.5.10
9.0.5.11: WebSphere Application Server traditional Version 9.0.5.11
APAR status
Closed as program error.
Error description
Created a web server from the admin console. The web server starts fine from the admin console. Attempting to start the web server with the command: startServer.sh webserver1 fails with error: ADMU3011E: Server launched but failed initialization. Server logs, startServer.log, and other log files under /opt/IBM/Websphere/Appserver/profile1/logs/webserver1 should contain failure information. - Running with the -trace option the startserver.log shows the command being executed: AH00094: Command line: '/srv/filenet/IBM/HTTPServer/bin/httpd -d /srv/filenet/IBM/HTTPServer -Dwas.status.socket=40805 -f /srv/filenet/IBM/HTTPServer/conf/httpd.conf' The "-Dwas.status.socket=40805" parameter is not a valid parameter for the httpd command. This parameter should not be part of the command.
Local fix
You can work around this issue by specifying the "-nowait" parameter. Run the command startServer.sh webserver1 -nowait to start the web server. When this parameter is specified the "-Dwas.status.socket=40805" keyword is not generated. - Keywords: httpd illegal option ihs stopserver
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM WebSphere Application * * Server * **************************************************************** * PROBLEM DESCRIPTION: Starting a web server using the * * startServer script failed although * * the web server actually started. * **************************************************************** * RECOMMENDATION: * **************************************************************** Starting a web server using the startServer script failed although the web server actually started. Example error is below: ADMU0128I: Starting tool with the MAN_oeisfntl70_01 profile ADMU3100I: Reading configuration for server: WEB_oeisfntl70 ADMU3200I: Server launched. Waiting for initialization status. ADMU3011E: Server launched but failed initialization. Server logs, startServer.log, and other log files under /srv/filenet/profiles/MAN_oeisfntl70_01/logs/WEB_oeisfntl70 should contain failure information.
Problem conclusion
The code is fixed to set the correct option to launch the web server. The fix for this APAR is currently targeted for inclusion in fix pack 9.0.0.8. Please refer to the Recommended Updates page for delivery information: http://www.ibm.com/support/docview.wss?rs=180&uid=swg27004980
Temporary fix
Run startServer using -nowait option.
Comments
APAR Information
APAR number
PI92142
Reported component name
WEBS APP SERV N
Reported component ID
5724H8800
Reported release
900
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-01-08
Closed date
2018-02-05
Last modified date
2018-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBS APP SERV N
Fixed component ID
5724H8800
Applicable component levels
R900 PSY
UP
Document Information
Modified date:
04 May 2022