IBM Support

PI91795: _CQ_OSLC_SESSION SESSION VARIABLE VALUE IS LOST AFTER CQRPC RECYCLE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When a CQWeb session is transferred to a new cqrpc process due
    to process recycling, the _CQ_OSLC_SESSION session variable is
    not transferred.
    This will cause unexpected results if hook code in the schema
    relies of the value of the session variable.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * ClearQuest Web                                               *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Under very rare circumstances, the _CQ_OSLC_SESSION session  *
    * variable is not set correctly when an OSLC request is made.  *
    * This could cause an OSLC request that depends on this value, *
    * such as an update, to fail.                                  *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • A fix is available in ClearQuest 9.0.1.5.
    The _CQ_OSLC_SESSION SESSION session variable is now always set
    when OSLC sessions are established and/or re-established.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI91795

  • Reported component name

    CLEARQUEST WIN

  • Reported component ID

    5724G3600

  • Reported release

    801

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-12-21

  • Closed date

    2018-11-29

  • Last modified date

    2018-11-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CLEARQUEST WIN

  • Fixed component ID

    5724G3600

Applicable component levels

  • R801 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud \u0026 Data Platform"},"Product":{"code":"SSSH5A","label":"Rational ClearQuest"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"801","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]