IBM Support

PI90296: ENHANCE EXTERNAL LOAD TO TREAT AS OFFLINE ANY ACCELERATOR THAT CANNOT BE REACHED ON THE NETWORK.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Currently the dual load component of the Loader will fail if it
    is unable to determine the status of an accelerator by calling
    the ACCEL_CONTROL_ACCELERATOR stored procedure.  With this
    enhancement, an accelerator that can not be reached on the
    network will instead be treated as offline.
    More specifically, when the ACCEL_CONTROL_ACCELERATOR stored
    procedure call fails with the following error, that accelerator
    will be treated as if it were offline:
    AQT10202I The _acceleratorName_ accelerator cannot be contacted
    over the network
    Treating such an accelerator as offline has the following
    impact.
    # If more than one accelerator is included in the load and at
    least one of them appears to be online, the online acclerators
    will be loaded.  In the past the above network error would have
    caused the load to fail.
    # If all accelerators appear to be offline during an IDAA_DUAL
    load, the setting of the ACCEL_WHEN_OFFLINE option will control
    whether the Loader fails or loads only DB2.  In the past the
    network error would have caused such a load to fail.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IBM DB2 Analytics Accelerator       *
    *                 Loader for z/OS.                             *
    ****************************************************************
    * PROBLEM DESCRIPTION: Currently the dual load component of    *
    *                      the Loader will fail if it is unable to *
    *                      determine the status of an accelerator  *
    *                      by calling the                          *
    *                      ACCEL_CONTROL_ACCELERATOR stored        *
    *                      procedure.  With this enhancement,      *
    *                      an accelerator that can not be reached  *
    *                      on the network will instead be          *
    *                      treated as offline. More specifically,  *
    *                      when the ACCEL_CONTROL_ACCELERATOR      *
    *                      stored procedure call fails with the    *
    *                      following error, that accelerator       *
    *                      will be treated as if it were offline:  *
    *                      AQT10202I The                           *
    *                       _acceleratorName_ accelerator cannot   *
    *                       be contacted over the network          *
    *                      Treating such an accelerator as         *
    *                      offline has the following impact.       *
    *                      - If more than one accelerator is       *
    *                       included in the load and at least one  *
    *                       of them appears to be online, the      *
    *                       online acclerators will be loaded.     *
    *                       In the past the above network error    *
    *                       would have caused the load to fail.    *
    *                      - If all accelerators appear to be      *
    *                       offline during an IDAA_DUAL load, the  *
    *                       setting of the ACCEL_WHEN_OFFLINE      *
    *                       option will control whether the        *
    *                       Loader fails or loads only DB2.  In    *
    *                       the past the network error would       *
    *                       have caused such a load to fail.       *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI90296

  • Reported component name

    IDAA LOADER ZOS

  • Reported component ID

    5639OLA00

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-11-15

  • Closed date

    2017-12-07

  • Last modified date

    2018-01-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    HLORUSQA
    

Fix information

  • Fixed component name

    IDAA LOADER ZOS

  • Fixed component ID

    5639OLA00

Applicable component levels

  • R210 PSY UI52504

       UP17/12/14 P F712

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSKRKK","label":"IBM Db2 Analytics Accelerator Loader for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
12 February 2021