IBM Support

PI89338: ABEND32E-11C IN OBJECT ANALYSIS SET TIMER FUNCTION

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • S32E ABEND in KO2EOJS2 (Object Analysis).
    
    S32E Explanation: When a program issued the STIMERM service
    routine, an error occurred. Register 15 contains a hexadecimal
    reason code.
    R15 reason code is x'0000011C'
    Meaning: The limit of concurrent STIMERM SET macro requests was
    exceeded.
    
    CI0970: OMEGAMON SUBTASK ABEND CODE=8432E000
    CI0971: PROGRAM NAME=KO2EOJAB
    
    S32E abend32e abends32e
    

Local fix

  • apply PTF when available
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM users of        *
    *                 component                                    *
    *                 - Object Analysis                            *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABEND32E-11C in Object Analysis set     *
    *                      timer function.                         *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    During stopping DB2 and OM Server, Object Analysis does not
    recognize the OM Server termination is in progress and continues
    thus causing the S32E-11C abend.
    

Problem conclusion

  • Change logic to prevent the abend. Recognize the OM Server
    termination is in progress and stop Object Analysis process.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI89338

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    540

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-10-24

  • Closed date

    2017-12-12

  • Last modified date

    2018-01-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI52617

Modules/Macros

  •    KO2EOJAB
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R540 PSY UI52617

       UP17/12/14 P F712

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
03 January 2018