A fix is available
APAR status
Closed as program error.
Error description
Change the threshold of EXTENT parameter for CHECK command from 0-123 to 0-251.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IBM IMS HALDB Toolkit V1.1. * **************************************************************** * PROBLEM DESCRIPTION: Change the threshold of EXTENT * * parameter for CHECK command from 0-123 * * to 0-251. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** The maximum number of extents per data set is 251 for VSAM, but the threshold of EXTENT parameter for CHECK command is from 0-123. So when the number of extents per data set is greater than 123, you cannnot get a warning or a critical warning correctly.
Problem conclusion
The threshold of EXTENT parameter for CHECK command has been changed from 0-123 to 0-251. ======================== = DOCUMENTATION CHANGE = ======================== IBM IMS Database Solution Pack for z/OS Version 2 Release 2 IMS High Availability Large Database Toolkit User's Guide (SC27-9038-00) and IBM IMS Database Utility Solution for z/OS Version 1 Release 1 IMS High Availability Large Database Toolkit User's Guide (SC27-9007-01) ---------------------------------------------------------------- Chapter 6. Using the HALDB Analyzer CHECK command parameters Description of parameter EXTENT has been modified as follows: Indicates the extent number that triggers a warning. The maximum number of extents allowed depends on the data management type. | VSAM: The maximum number of extents per data set is 251. | The maximum number of extents per volume is 123. | OSAM: The maximum number of extents per data set depends on | the version of IMS; approximately 60 for IMS V13, | and approximately 120 for IMS V14 and later. | The maximum number of extents per volume is 16. When no more extents are possible, an attempt to obtain a new one creates an out-of-space condition, which leads to an 844 IMS abend. The purpose of the EXTENT parameter settings is to prevent this occurrence. Format: (lll,hhh) lll Sets the low threshold. Specify a number in the range of | 0 - 251. You will get a warning when this value is exceeded. If you specify a value of 0, this warning is suppressed. hhh Sets the high threshold. Specify a number in the range | of 0 - 251. You will get a critical warning when this value is exceeded. If you specify a value of 0, this warning is suppressed. Default value: None. : :
Temporary fix
Comments
APAR Information
APAR number
PI88980
Reported component name
IMS HA DB TOOLK
Reported component ID
5655DBU01
Reported release
110
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-10-17
Closed date
2017-10-31
Last modified date
2017-12-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI51555
Modules/Macros
IHCULEV0 IHCYCCDF
Fix information
Fixed component name
IMS HA DB TOOLK
Fixed component ID
5655DBU01
Applicable component levels
R110 PSY UI51555
UP17/11/02 P F711
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.