IBM Support

PI88401: UNCOMMITTED DROPS CAUSE ARY REPOSITORY TO NOT BE UPDATED

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Customer discovered that uncommitted drops cause the log scan
    step to fail and consequently the repository does not get
    updated.
    The solution is to set the resolve incomplete UOWS flag to
    'YES'.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IBM DB2 Recovery Expert z/OS.       *
    ****************************************************************
    * PROBLEM DESCRIPTION: Customer discovered that uncommitted    *
    *                      drops cause the log scan step to fail   *
    *                      and consequently the repository does    *
    *                      not get updated.                        *
    *                      The solution is to set the resolve      *
    *                      incomplete UOWS flag to 'YES'.          *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI88401

  • Reported component name

    DB2 REC EXPERT

  • Reported component ID

    5697H7400

  • Reported release

    320

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-10-04

  • Closed date

    2017-11-06

  • Last modified date

    2017-12-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    ARYBIND1
    

Fix information

  • Fixed component name

    DB2 REC EXPERT

  • Fixed component ID

    5697H7400

Applicable component levels

  • R320 PSY UI51711

       UP17/11/15 P F711

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2.0"}]

Document Information

Modified date: