IBM Support

PI88307: ABEND0C4 IN DB2PM CSECT FPEUCXFX USING THE FIELD AUXILIARY COMMAND

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ABEND0C4 in FPEUCXFX may occur when the DB2PM FIELD auxiliary
    command is used and zero is specified as the self defining
    section number. Alternatively, specifying zero as the self
    defining section number may cause FIELD processing to not filter
    records as expected, resulting in INCORROUT
    

Local fix

  • apply PTF
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2 PM Users of       *
    *                 component batch record trace.                *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABEND0C4 in FPEUCXFX when using the     *
    *                      record trace FIELD auxiliary command.   *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    The third parameter of the FIELD auxiliary command is the self
    defining data section number that the FIELD command comparison
    operation is performed against.  A value of zero is defined as
    having the special meaning of applying to the first product
    section of the record instead of a data section.  The code was
    not handling this case correctly, typically resulting in an
    ABEND0C4.  Alternatively, the filtering may not work as
    intended, resulting in the requested record trace being
    incorrect.
    

Problem conclusion

  • The code has been changed to recognize that self defining
    section zero applies to the product section.  Furthermore,
    the repeating group number is ignored in this case, since
    the product section does not have repeating data groups.
    
    Search Keywords:
    INCORROUT ABEND0C4
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI88307

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    540

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-10-03

  • Closed date

    2018-01-26

  • Last modified date

    2018-02-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI53479 UI53480

Modules/Macros

  •    FPEUCXFX
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R530 PSY UI53479

       UP18/01/30 P F801

  • R540 PSY UI53480

       UP18/01/30 P F801

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4.0"}]

Document Information

Modified date: