A fix is available
APAR status
Closed as program error.
Error description
ABEND0C4 in FPEUCXFX may occur when the DB2PM FIELD auxiliary command is used and zero is specified as the self defining section number. Alternatively, specifying zero as the self defining section number may cause FIELD processing to not filter records as expected, resulting in INCORROUT
Local fix
apply PTF
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2 PM Users of * * component batch record trace. * **************************************************************** * PROBLEM DESCRIPTION: ABEND0C4 in FPEUCXFX when using the * * record trace FIELD auxiliary command. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** The third parameter of the FIELD auxiliary command is the self defining data section number that the FIELD command comparison operation is performed against. A value of zero is defined as having the special meaning of applying to the first product section of the record instead of a data section. The code was not handling this case correctly, typically resulting in an ABEND0C4. Alternatively, the filtering may not work as intended, resulting in the requested record trace being incorrect.
Problem conclusion
The code has been changed to recognize that self defining section zero applies to the product section. Furthermore, the repeating group number is ignored in this case, since the product section does not have repeating data groups. Search Keywords: INCORROUT ABEND0C4
Temporary fix
Comments
APAR Information
APAR number
PI88307
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
540
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-10-03
Closed date
2018-01-26
Last modified date
2018-02-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI53479 UI53480
Modules/Macros
FPEUCXFX
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4.0"}]
Document Information
Modified date:
31 March 2021